{"id":93937,"date":"2020-10-23T13:53:44","date_gmt":"2020-10-23T11:53:44","guid":{"rendered":"https:\/\/www.aquariumcomputer.com\/de\/?post_type=kb&#038;p=93937"},"modified":"2020-10-23T13:53:44","modified_gmt":"2020-10-23T11:53:44","slug":"so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein","status":"publish","type":"kb","link":"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/","title":{"rendered":"So richten Sie Dosierzeiten f\u00fcr eine Dosierpumpe ein"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2017\/10\/Icon-GHL-Connect_rounded-corners-150x150.webp\" class=\"vc_single_image-img attachment-thumbnail\" alt=\"\" title=\"Icon GHL Connect_rounded corners\" srcset=\"https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2017\/10\/Icon-GHL-Connect_rounded-corners-150x150.webp 150w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2017\/10\/Icon-GHL-Connect_rounded-corners-120x120.webp 120w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2017\/10\/Icon-GHL-Connect_rounded-corners-png.webp 300w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\"  data-dt-location=\"https:\/\/www.aquariumcomputer.com\/de-2\/ghl-connect\/icon-ghl-connect_rounded-corners\/\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h3>\u00dcber Dosierzeiten<\/h3>\n<p>Die in diesem Artikel beschriebenen Schritte sind sowohl f\u00fcr ProfiLux-Besitzer als auch f\u00fcr Besitzer von Standalone-GHL-Dosern anwendbar.<\/p>\n<p>ProfiLux 4 \/ 4e Controller k\u00f6nnen so eingestellt werden, dass sie verschiedene Arten von Dosierpumpen wie GHL-Doser und traditionelle EIN\/AUS-Dosierger\u00e4te steuern k\u00f6nnen. Abh\u00e4ngig von der Art der Dosierpumpe, die Sie verwenden m\u00f6chten, variieren die anf\u00e4nglichen Einrichtungsschritte.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><span class=\"mkb-shortcode-container\">\t\t<div class=\"mkb-info\">\n\t\t\t<div class=\"mkb-info__icon\">\n\t\t\t\t<i class=\"fa fa-info-circle fa-lg\"><\/i>\n\t\t\t<\/div>\n\t\t\t<div class=\"mkb-info__content\">\n\t\t\t\t<\/p>\n<h3>ProfiLux-Besitzer: Sie dosieren mit einem GHL-Doser?<\/h3>\n<p>Wenn Sie einen ProfiLux-Controller haben und mit einem GHL-Doser dosieren m\u00f6chten, m\u00fcssen Sie den Doser zun\u00e4chst dem ProfiLux zuweisen. Befolgen Sie dazu die Schritte zur Zuweisung von PAB-Ger\u00e4ten, bevor Sie fortfahren.\t\t\t<\/div>\n\t\t<\/div>\n\t<\/span><span class=\"mkb-shortcode-container\">\t\t\t<div class=\"mkb-related-content\">\n\t\t\t\t<div class=\"mkb-related-content-title\">Siehe auch:<\/div>\n\t\t\t\t<ul class=\"mkb-related-content-list\">\n\t\t\t\t\t\t\t\t\t\t\t<li><a href=\"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/zuordnen-von-pab-geraeten\/\">So weisen Sie PAB Ger\u00e4te zu<\/a><\/li>\n\t\t\t\t\t\t\t\t\t<\/ul>\n\t\t\t<\/div>\n\t\t<\/span><\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><span class=\"mkb-shortcode-container\">\t\t<div class=\"mkb-info\">\n\t\t\t<div class=\"mkb-info__icon\">\n\t\t\t\t<i class=\"fa fa-info-circle fa-lg\"><\/i>\n\t\t\t<\/div>\n\t\t\t<div class=\"mkb-info__content\">\n\t\t\t\t<\/p>\n<h3>ProfiLux-Besitzer: Verwenden Sie ein herk\u00f6mmliches Dosierger\u00e4t?<\/h3>\n<p>Wenn Sie ein traditionelles EIN\/AUS-Dosierger\u00e4t haben, wie z.B. von BulkReefSupply verkauft, beachten Sie bitte, dass dieses Ger\u00e4t an eine steuerbare Steckdose angeschlossen werden muss. Dies erm\u00f6glicht es dem ProfiLux, diese Steckdose w\u00e4hrend einer geplanten Dosierung zu aktivieren.\t\t\t<\/div>\n\t\t<\/div>\n\t<\/span><\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h3>Allgemeine Dosierpumpeneinstellungen konfigurieren<\/h3>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<ol>\n<li>Klicken Sie auf das <strong>Men\u00fc<\/strong>-Symbol, w\u00e4hlen Sie <strong>Dosierpumpen<\/strong>, w\u00e4hlen Sie eine <strong>Dosierpumpe<\/strong> aus<\/li>\n<li>Geben Sie eine Beschreibung f\u00fcr diese Pumpe ein<\/li>\n<li>W\u00e4hlen Sie <em>Beh\u00e4lter wird<\/em><strong> geleert<\/strong><\/li>\n<\/ol>\n<p><em>&#8222;geleert&#8220; bedeutet, dass der Dosierbeh\u00e4lter mit jeder Dosierung geleert wird<\/em><br \/>\n<em>&#8222;gef\u00fcllt&#8220; bedeutet, dass der Dosierbeh\u00e4lter mit Abwasser gef\u00fcllt wird<\/em><\/p>\n<p>4. Wenn Sie Ihre Dosierungen aufzeichnen lassen m\u00f6chten, <strong>aktivieren<\/strong> Sie die Option Dosierungen aufzeichnen wie unten gezeigt<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"511\" height=\"1024\" src=\"https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-1-511x1024.webp\" class=\"vc_single_image-img attachment-large\" alt=\"\" title=\"Dosing pump setup 1\" srcset=\"https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-1-511x1024.webp 511w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-1-150x300.webp 150w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-1-768x1538.webp 768w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-1-767x1536.webp 767w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-1-1023x2048.webp 1023w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-1-scaled.webp 1279w\" sizes=\"auto, (max-width: 511px) 100vw, 511px\"  data-dt-location=\"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/dosing-pump-setup-1\/\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-6\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"511\" height=\"1024\" src=\"https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-2-511x1024.webp\" class=\"vc_single_image-img attachment-large\" alt=\"\" title=\"Dosing pump setup 2\" srcset=\"https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-2-511x1024.webp 511w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-2-150x300.webp 150w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-2-768x1538.webp 768w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-2-767x1536.webp 767w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-2-1023x2048.webp 1023w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-2-scaled.webp 1279w\" sizes=\"auto, (max-width: 511px) 100vw, 511px\"  data-dt-location=\"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/dosing-pump-setup-2\/\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_empty_space\"   style=\"height: 32px\"><span class=\"vc_empty_space_inner\"><\/span><\/div><\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-8\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>5. Geben Sie die <strong>Kapazit\u00e4t<\/strong> Ihres Dosierbeh\u00e4lters ein, klicken Sie dann auf <strong>BEH\u00c4LTER NACHF\u00dcLLEN<\/strong> und geben Sie ein, wie viele ml sich <span style=\"text-decoration: underline;\">jetzt in Ihrem Beh\u00e4lter befinden<\/span>, klicken Sie dann auf <strong>SPEICHERN<\/strong><\/p>\n<p>If you would like the ProfiLux or Standalone Doser to notify you when the container is at or below the minimum threshold,\u00a0<strong>enable<\/strong> the option &#8222;Alarm if below minimum&#8220; and specify the min.point.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-4\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"709\" src=\"https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-3-1024x709.webp\" class=\"vc_single_image-img attachment-large\" alt=\"\" title=\"Dosing pump setup 3\" srcset=\"https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-3-1024x709.webp 1024w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-3-300x208.webp 300w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-3-768x532.webp 768w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-3-jpg.webp 1326w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\"  data-dt-location=\"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/dosing-pump-setup-3\/\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h3>GHL-Doser Pumpengeschwindigkeit einstellen<\/h3>\n<p>Wenn Sie einen GHL-Doser verwenden, haben Sie die M\u00f6glichkeit, die Geschwindigkeit der Pumpe zu \u00e4ndern. Die Geschwindigkeit, die Sie w\u00e4hlen, h\u00e4ngt von der Menge ab, die Sie bei jeder Dosierung dosieren m\u00f6chten. \u00dcberspringen Sie diesen Schritt, wenn Sie eine Nicht-GHL-Dosierpumpe verwenden.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<ol>\n<li>W\u00e4hlen Sie im Abschnitt <em>Pumpen-Einstellungen<\/em> die gew\u00fcnschte <strong>Max. Geschwindigkeit<\/strong><\/li>\n<\/ol>\n<p><a href=\"https:\/\/www.aquariumcomputer.com\/de\/wp-content\/uploads\/sites\/4\/2020\/10\/Pump-calibration-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-93947\" src=\"https:\/\/www.aquariumcomputer.com\/de\/wp-content\/uploads\/sites\/4\/2020\/10\/Pump-calibration-1-300x128.jpg\" alt=\"\" width=\"300\" height=\"128\" \/><\/a><\/p>\n\n\t\t<\/div>\n\t<\/div>\n<span class=\"mkb-shortcode-container\">\t\t<div class=\"mkb-tip\">\n\t\t\t<div class=\"mkb-tip__icon\">\n\t\t\t\t<i class=\"fa fa-lightbulb-o fa-lg\"><\/i>\n\t\t\t<\/div>\n\t\t\t<div class=\"mkb-tip__content\">\n\t\t\t\t<strong>Wann w\u00e4hlen Sie welche Geschwindigkeit&#8230;<\/strong><\/p>\n<p>Die Geschwindigkeit, mit der Sie Ihre GHL-Pumpe betreiben wollen, h\u00e4ngt von der Menge ab, die Sie in einem einzigen Zyklus dosieren m\u00f6chten, sowie von der erforderlichen Genauigkeit. Hier sind einige Empfehlungen zur Wahl der richtigen Geschwindigkeit:<\/p>\n<p><strong>Geschwindigkeit 0:<\/strong> W\u00e4hlen Sie dies, wenn Sie Einzeldosierungen mit weniger als 0,5ml vornehmen m\u00f6chten<strong><br \/>\nGeschwindigkeit 0 oder 1:<\/strong> W\u00e4hlen Sie dies, wenn Sie 0,1ml Dosierschritte ben\u00f6tigen; 4,7ml oder 15,3ml<br \/>\n<strong>Geschwindigkeit 2 oder 3:<\/strong> W\u00e4hlen Sie dies, wenn Ihre Einzeldosis 1ml oder mehr betr\u00e4gt.\t\t\t<\/div>\n\t\t<\/div>\n\t<\/span>\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>2. Bet\u00e4tigen Sie <strong>SPEICHERN<\/strong>, um die neue Pumpengeschwindigkeit einzustellen.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h3>Kalibrieren der Dosierpumpe<\/h3>\n<p>Damit die Dosierpumpe genaue Dosiermengen liefern kann, muss sie zun\u00e4chst kalibriert werden.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<span class=\"mkb-shortcode-container\">\t\t<div class=\"mkb-info\">\n\t\t\t<div class=\"mkb-info__icon\">\n\t\t\t\t<i class=\"fa fa-info-circle fa-lg\"><\/i>\n\t\t\t<\/div>\n\t\t\t<div class=\"mkb-info__content\">\n\t\t\t\t<strong>Vorbereitung der Kalibrierung<\/strong><\/p>\n<p>Tun Sie Folgendes, bevor Sie weitermachen:<\/p>\n<ul>\n<li>Bereiten Sie einen Becher mit Wasser vor, damit die Pumpe w\u00e4hrend der Kalibrierung etwas hat, aus dem sie Wasser entnehmen kann.<\/li>\n<li>Dosierleitungen abschneiden und installieren, dann beide Enden des Schlauchs entl\u00fcften<\/li>\n<li>Einen Messzylinder, Messbecher oder eine digitale Waage zur Messung der Wassermenge verwenden<\/li>\n<\/ul>\n<p>Wenn Sie eine herk\u00f6mmliche EIN\/AUS-Dosierpumpe haben, schalten Sie dieses Dosierger\u00e4t 1 Minute lang ein und notieren Sie die dosierte Menge in ml. Sie ben\u00f6tigen diese Information sp\u00e4ter.\t\t\t<\/div>\n\t\t<\/div>\n\t<\/span>\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>1. Bet\u00e4tigen Sie <strong>PUMPE KALIBRIEREN<br \/>\n<\/strong><a href=\"https:\/\/www.aquariumcomputer.com\/de\/wp-content\/uploads\/sites\/4\/2020\/10\/Pump-calibration-2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-93948\" src=\"https:\/\/www.aquariumcomputer.com\/de\/wp-content\/uploads\/sites\/4\/2020\/10\/Pump-calibration-2-300x32.jpg\" alt=\"\" width=\"300\" height=\"32\" \/><\/a><\/p>\n<p><em>Die Pumpe l\u00e4uft nun 1 Minute lang<\/em><\/p>\n<p>2. Pr\u00fcfen Sie, wie viele ml dosiert wurden, und geben Sie diese Menge in das Feld <em>Durchflussmenge der Pumpe<\/em> ein<br \/>\n<a href=\"https:\/\/www.aquariumcomputer.com\/de\/wp-content\/uploads\/sites\/4\/2020\/10\/Pump-calibration-3.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-93946\" src=\"https:\/\/www.aquariumcomputer.com\/de\/wp-content\/uploads\/sites\/4\/2020\/10\/Pump-calibration-3-300x78.jpg\" alt=\"\" width=\"300\" height=\"78\" \/><\/a><\/p>\n<p>3. Klicken Sie auf <strong>SPEICHERN<\/strong><\/p>\n<p>Wenn Sie weitere Pumpen haben, die kalibriert werden m\u00fcssen, wiederholen Sie diese Schritte.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h3>Einen Dosierplan erstellen<\/h3>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-8\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<ol>\n<li>Klicken Sie auf die Registerkarte <strong>Dosierplan<\/strong><\/li>\n<li>W\u00e4hlen Sie einen Dosierzeiten-Modus<\/li>\n<\/ol>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-4\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"833\" src=\"https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-4-1024x833.webp\" class=\"vc_single_image-img attachment-large\" alt=\"\" title=\"Dosing pump setup 4\" srcset=\"https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-4-1024x833.webp 1024w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-4-300x244.webp 300w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-4-768x625.webp 768w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-4-1536x1250.webp 1536w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-4-jpg.webp 1780w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\"  data-dt-location=\"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/dosing-pump-setup-4\/\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><span class=\"mkb-shortcode-container\">\t\t<div class=\"mkb-tip\">\n\t\t\t<div class=\"mkb-tip__icon\">\n\t\t\t\t<i class=\"fa fa-lightbulb-o fa-lg\"><\/i>\n\t\t\t<\/div>\n\t\t\t<div class=\"mkb-tip__content\">\n\t\t\t\t<strong>Die Dorsierzeiten-Modi<\/strong><\/p>\n<p>Der von Ihnen gew\u00e4hlte Modus h\u00e4ngt davon ab, wie Sie Ihren Dosierplan einstellen m\u00f6chten<\/p>\n<p><span style=\"color: #1b88ce\"><strong>Automatisch:<\/strong><\/span> Erm\u00f6glicht es Ihnen, die Anzahl der Dosierungen pro Tag, die Menge pro Dosierung und den Zeitpunkt der ersten Dosierung anzugeben.<br \/>\n<em>Wenn Sie beispielsweise 50 ml dosieren m\u00f6chten, k\u00f6nnen Sie die Pumpe auf <strong>5 Dosierungen pro Tag<\/strong> und <strong>10 ml pro Dosierung<\/strong> einstellen; 5 x 10 ml = 50 ml Gesamtdosis pro Tag. Die einzelnen Dosierungen werden gleichm\u00e4\u00dfig \u00fcber ein Zeitfenster von 24 Stunden verteilt.<\/em><\/p>\n<p><span style=\"color: #1b88ce\"><strong>Individuell:<\/strong><\/span> Erm\u00f6glicht es Ihnen, die genaue Zeit und Menge der Dosierung\/en anzugeben.\t\t\t<\/div>\n\t\t<\/div>\n\t<\/span><\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-8\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>3. W\u00e4hlen Sie einen Tagesmodus und bet\u00e4tigen Sie dann <strong>SPEICHERN<\/strong><\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><div class=\"wpb_column vc_column_container vc_col-sm-4\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_center\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"658\" src=\"https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-5-1024x658.webp\" class=\"vc_single_image-img attachment-large\" alt=\"\" title=\"Dosing pump setup 5\" srcset=\"https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-5-1024x658.webp 1024w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-5-300x193.webp 300w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-5-768x493.webp 768w, https:\/\/www.aquariumcomputer.com\/de-2\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-5-jpg.webp 1439w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\"  data-dt-location=\"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/dosing-pump-setup-5\/\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><span class=\"mkb-shortcode-container\">\t\t<div class=\"mkb-tip\">\n\t\t\t<div class=\"mkb-tip__icon\">\n\t\t\t\t<i class=\"fa fa-lightbulb-o fa-lg\"><\/i>\n\t\t\t<\/div>\n\t\t\t<div class=\"mkb-tip__content\">\n\t\t\t\t<\/p>\n<h4>\u00dcber den Tagemodus<\/h4>\n<p>Der von Ihnen gew\u00e4hlte Tagemodus h\u00e4ngt davon ab, wie Sie den Zeitplan ausf\u00fchren m\u00f6chten<\/p>\n<p><strong>Spezielle Wochentage:<\/strong> Erm\u00f6glicht Ihnen die Auswahl der Wochentage, an denen diese Zeitschaltuhr ausgef\u00fchrt werden soll<br \/>\n<strong>Tage-Intervalle:<\/strong> Hiermit k\u00f6nnen Sie w\u00e4hlen, wie oft diese Zeitschaltuhr in Intervallen ausgef\u00fchrt werden soll.<\/p>\n<p>Zum Beispiel, <em>Wiederholung alle<\/em> 3 Tage = Zeitschaltuhr wird alle 3 Tage laufen<br \/>\n<em>Beginnend in<\/em> &#8212; ist eine Verz\u00f6gerung. Wenn Sie den Start der Zeitschaltuhr verz\u00f6gern m\u00f6chten, geben Sie an, um wie viele Tage.\t\t\t<\/div>\n\t\t<\/div>\n\t<\/span><\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><span class=\"mkb-shortcode-container\">\t\t<div class=\"mkb-info\">\n\t\t\t<div class=\"mkb-info__icon\">\n\t\t\t\t<i class=\"fa fa-info-circle fa-lg\"><\/i>\n\t\t\t<\/div>\n\t\t\t<div class=\"mkb-info__content\">\n\t\t\t\t<strong>LETZTER SCHRITT f\u00fcr traditionelle EIN\/AUS-Dosierger\u00e4te<\/strong><\/p>\n<ol>\n<li>Schlie\u00dfen Sie Ihr Dosierger\u00e4t an eine verf\u00fcgbare Steckdose Ihrer Powerbar an.<\/li>\n<li>Klicken Sie auf die Zur\u00fcck-Pfeiltaste, klicken Sie auf das <strong>Men\u00fc<\/strong>-Symbol und w\u00e4hlen Sie <strong>Schaltkan\u00e4le<\/strong><\/li>\n<li>W\u00e4hlen Sie die Steckdose, an die die Pumpe angeschlossen ist<\/li>\n<li>Stellen Sie die Funktion auf <strong>Dosierpumpe<\/strong> ein, w\u00e4hlen Sie die Pumpennummer, die Sie zur Erstellung des Dosierplans verwendet haben und best\u00e4tigen Sie mit <strong>SPEICHERN<\/strong><\/li>\n<\/ol>\n<p><a href=\"https:\/\/www.aquariumcomputer.com\/de\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-Trad-doser.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-93945\" src=\"https:\/\/www.aquariumcomputer.com\/de\/wp-content\/uploads\/sites\/4\/2020\/10\/Dosing-pump-setup-Trad-doser-300x113.jpg\" alt=\"\" width=\"300\" height=\"113\" \/><\/a>\t\t\t<\/div>\n\t\t<\/div>\n\t<\/span><\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>\u00dcber Dosierzeiten Die in diesem Artikel beschriebenen Schritte sind sowohl f\u00fcr ProfiLux-Besitzer als auch f\u00fcr Besitzer von Standalone-GHL-Dosern anwendbar. ProfiLux 4 \/ 4e Controller k\u00f6nnen so eingestellt werden, dass sie verschiedene Arten von Dosierpumpen wie GHL-Doser und traditionelle EIN\/AUS-Dosierger\u00e4te steuern k\u00f6nnen. Abh\u00e4ngig von der Art der Dosierpumpe, die Sie verwenden m\u00f6chten, variieren die anf\u00e4nglichen Einrichtungsschritte.&hellip;<\/p>\n","protected":false},"author":241,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"kbtopic":[42,43,59,68,36,37,39,41],"kbtag":[],"class_list":["post-93937","kb","type-kb","status-publish","hentry","kbtopic-ghl-doser-2-1","kbtopic-ghl-doser-2-2-maxi","kbtopic-profilux-4e","kbtopic-ghl-connect","kbtopic-profilux-3","kbtopic-profilux-4","kbtopic-ghl-doser","kbtopic-ghl-doser-2","description-off"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>So richten Sie Dosierzeiten f\u00fcr eine Dosierpumpe ein - GHL Advanced Technology<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"So richten Sie Dosierzeiten f\u00fcr eine Dosierpumpe ein - GHL Advanced Technology\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/\" \/>\n<meta property=\"og:site_name\" content=\"GHL Advanced Technology\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.aquariumcomputer.com\/de\/wp-content\/uploads\/sites\/4\/2020\/10\/Pump-calibration-1-300x128.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"6\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/knowledge-base\\\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\\\/\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/knowledge-base\\\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\\\/\",\"name\":\"So richten Sie Dosierzeiten f\u00fcr eine Dosierpumpe ein - GHL Advanced Technology\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/knowledge-base\\\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/knowledge-base\\\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2020\\\/10\\\/Pump-calibration-1-300x128.jpg\",\"datePublished\":\"2020-10-23T11:53:44+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/knowledge-base\\\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/knowledge-base\\\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/knowledge-base\\\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2020\\\/10\\\/Pump-calibration-1-300x128.jpg\",\"contentUrl\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2020\\\/10\\\/Pump-calibration-1-300x128.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/knowledge-base\\\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"So richten Sie Dosierzeiten f\u00fcr eine Dosierpumpe ein\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/#website\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/\",\"name\":\"GHL Advanced Technology\",\"description\":\"High-Tech f\u00fcr Aquarien Made in Germany seit 1998\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/#organization\"},\"alternateName\":\"GHL\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/#organization\",\"name\":\"GHL\",\"alternateName\":\"GHL\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2015\\\/03\\\/WebClipIcon-e1426846616179.png\",\"contentUrl\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2015\\\/03\\\/WebClipIcon-e1426846616179.png\",\"width\":144,\"height\":144,\"caption\":\"GHL\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de-2\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"So richten Sie Dosierzeiten f\u00fcr eine Dosierpumpe ein - GHL Advanced Technology","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/","og_locale":"de_DE","og_type":"article","og_title":"So richten Sie Dosierzeiten f\u00fcr eine Dosierpumpe ein - GHL Advanced Technology","og_url":"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/","og_site_name":"GHL Advanced Technology","og_image":[{"url":"https:\/\/www.aquariumcomputer.com\/de\/wp-content\/uploads\/sites\/4\/2020\/10\/Pump-calibration-1-300x128.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"6\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/","url":"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/","name":"So richten Sie Dosierzeiten f\u00fcr eine Dosierpumpe ein - GHL Advanced Technology","isPartOf":{"@id":"https:\/\/www.aquariumcomputer.com\/de-2\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/#primaryimage"},"image":{"@id":"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/#primaryimage"},"thumbnailUrl":"https:\/\/www.aquariumcomputer.com\/de\/wp-content\/uploads\/sites\/4\/2020\/10\/Pump-calibration-1-300x128.jpg","datePublished":"2020-10-23T11:53:44+00:00","breadcrumb":{"@id":"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/#primaryimage","url":"https:\/\/www.aquariumcomputer.com\/de\/wp-content\/uploads\/sites\/4\/2020\/10\/Pump-calibration-1-300x128.jpg","contentUrl":"https:\/\/www.aquariumcomputer.com\/de\/wp-content\/uploads\/sites\/4\/2020\/10\/Pump-calibration-1-300x128.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/www.aquariumcomputer.com\/de-2\/knowledge-base\/so-richten-sie-dosierzeiten-fuer-eine-dosierpumpe-ein\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.aquariumcomputer.com\/de-2\/"},{"@type":"ListItem","position":2,"name":"So richten Sie Dosierzeiten f\u00fcr eine Dosierpumpe ein"}]},{"@type":"WebSite","@id":"https:\/\/www.aquariumcomputer.com\/de-2\/#website","url":"https:\/\/www.aquariumcomputer.com\/de-2\/","name":"GHL Advanced Technology","description":"High-Tech f\u00fcr Aquarien Made in Germany seit 1998","publisher":{"@id":"https:\/\/www.aquariumcomputer.com\/de-2\/#organization"},"alternateName":"GHL","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aquariumcomputer.com\/de-2\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/www.aquariumcomputer.com\/de-2\/#organization","name":"GHL","alternateName":"GHL","url":"https:\/\/www.aquariumcomputer.com\/de-2\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/www.aquariumcomputer.com\/de-2\/#\/schema\/logo\/image\/","url":"https:\/\/www.aquariumcomputer.com\/de\/wp-content\/uploads\/sites\/4\/2015\/03\/WebClipIcon-e1426846616179.png","contentUrl":"https:\/\/www.aquariumcomputer.com\/de\/wp-content\/uploads\/sites\/4\/2015\/03\/WebClipIcon-e1426846616179.png","width":144,"height":144,"caption":"GHL"},"image":{"@id":"https:\/\/www.aquariumcomputer.com\/de-2\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/www.aquariumcomputer.com\/de-2\/wp-json\/wp\/v2\/kb\/93937","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aquariumcomputer.com\/de-2\/wp-json\/wp\/v2\/kb"}],"about":[{"href":"https:\/\/www.aquariumcomputer.com\/de-2\/wp-json\/wp\/v2\/types\/kb"}],"author":[{"embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de-2\/wp-json\/wp\/v2\/users\/241"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de-2\/wp-json\/wp\/v2\/comments?post=93937"}],"version-history":[{"count":6,"href":"https:\/\/www.aquariumcomputer.com\/de-2\/wp-json\/wp\/v2\/kb\/93937\/revisions"}],"predecessor-version":[{"id":93952,"href":"https:\/\/www.aquariumcomputer.com\/de-2\/wp-json\/wp\/v2\/kb\/93937\/revisions\/93952"}],"wp:attachment":[{"href":"https:\/\/www.aquariumcomputer.com\/de-2\/wp-json\/wp\/v2\/media?parent=93937"}],"wp:term":[{"taxonomy":"kbtopic","embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de-2\/wp-json\/wp\/v2\/kbtopic?post=93937"},{"taxonomy":"kbtag","embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de-2\/wp-json\/wp\/v2\/kbtag?post=93937"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}