{"id":112789,"date":"2026-07-08T12:00:25","date_gmt":"2026-07-08T10:00:25","guid":{"rendered":"https:\/\/www.aquariumcomputer.com\/knowledge-base\/rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle\/"},"modified":"2026-09-14T14:08:47","modified_gmt":"2026-09-14T12:08:47","password":"","slug":"rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle","status":"publish","type":"docs","link":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle\/","title":{"rendered":"R\u00fcckf\u00f6rderpumpensteuerung \u2013 \u00dcberblick &#038; Anwendungsf\u00e4lle"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Zusammenfassung<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Der ProfiLux unterst\u00fctzt mehrere Methoden zur Steuerung einer R\u00fcckf\u00f6rderpumpe, abh\u00e4ngig von Ihrem Pumpentyp und dem gew\u00fcnschten Grad der Kontrolle. Dieser Artikel erkl\u00e4rt die verf\u00fcgbaren Optionen und hilft Ihnen, den passenden Ansatz f\u00fcr Ihr Setup zu finden.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Gilt f\u00fcr<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<ul>\n<li>ProfiLux 4 Serie (inkl. Industrial Line \/ IL)<\/li>\n<li>ProfiLux 3 Serie<\/li>\n<li><strong>Software:<\/strong>\n<ul>\n<li>GHL Connect (App, Webinterface, myGHL)<\/li>\n<li>GHL Control Center<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Steuerungsmethoden<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h3>GHL Versia Flow<\/h3>\n<p>Die Versia Flow ist GHLs eigene drehzahlvariable R\u00fcckf\u00f6rderpumpe. Sie wird \u00fcber den Versia Controller und PAB an den ProfiLux angeschlossen und vollst\u00e4ndig \u00fcber Pumpengruppen verwaltet. <\/p>\n<p><strong>Siehe:<\/strong> <a href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/versia-einrichtungsanleitung\/\">Versia \u2013 Einrichtungsanleitung<\/a><\/p>\n<h3>Ein\/Aus-Steuerung \u00fcber Powerbar-Steckdose<\/h3>\n<p>Die einfachste Option. Die R\u00fcckf\u00f6rderpumpe wird in eine Powerbar-Steckdose gesteckt und vom ProfiLux ein- oder ausgeschaltet. Nutzen Sie diese Option, wenn Ihre Pumpe keine Drehzahlregelung unterst\u00fctzt.  <\/p>\n<p>Die Steckdose kann so konfiguriert werden, dass sie w\u00e4hrend Futterpausen oder Wartung automatisch abschaltet, und bei Bedarf mit einer Zeitschaltuhr geplant werden.<\/p>\n<p><strong>Siehe:<\/strong> <a href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/schaltkanaele-konfigurationsanleitung\/\"><\/a><a href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/pumpengruppen-konfigurationsanleitung\/\">Schaltkan\u00e4le \u2013 Konfigurationsanleitung<\/a><\/p>\n<h3>Durchfluss-Zeitpl\u00e4ne und -Programme \u00fcber Pumpengruppen<\/h3>\n<p>Sobald Ihre R\u00fcckf\u00f6rderpumpe angeschlossen und einem Pumpenkanal zugewiesen ist, erm\u00f6glichen Ihnen Pumpengruppen die Erstellung von Zeitpl\u00e4nen, die Konfiguration der n\u00e4chtlichen Durchflussreduzierung und die Festlegung von Reaktionen auf Systemereignisse, einschlie\u00dflich Futterpausen und Wartung. Nutzen Sie den Modus <em>Permanent<\/em> oder <em>Permanent gegenl\u00e4ufig<\/em> f\u00fcr den Betrieb der R\u00fcckf\u00f6rderpumpe mit konstanter Drehzahl innerhalb einer Gruppe. <\/p>\n<p><strong>Siehe:<\/strong> <a href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/pumpengruppen-konfigurationsanleitung\/\">Pumpengruppen \u2013 Konfigurationsanleitung<\/a><\/p>\n<h3>Variable Drehzahlregelung \u00fcber 1-10V-Schnittstelle<\/h3>\n<p>Wenn Ihre R\u00fcckf\u00f6rderpumpe die 1-10V-Drehzahlregelung unterst\u00fctzt, kann der ProfiLux die Pumpendrehzahl direkt regeln. So k\u00f6nnen Sie Minimal- und Maximaldrehzahlen festlegen, auf Futterpausen und Wartung reagieren und einen Durchflusssensor nutzen, um unabh\u00e4ngig von \u00c4nderungen der F\u00f6rderh\u00f6he einen konstanten Durchfluss aufrechtzuerhalten. <\/p>\n<p><strong>Siehe:<\/strong> <a href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/1-10v-pumpensteuerung-einrichtungsanleitung\/\">1-10V-Pumpensteuerung \u2013 Einrichtungsanleitung<\/a><\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Hinweise<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<ul>\n<li><strong>Leckage-Erkennung:<\/strong> Der ProfiLux kann die R\u00fcckf\u00f6rderpumpe automatisch abschalten, wenn \u00fcber einen angeschlossenen Leckagesensor eine Leckage erkannt wird. Dies wird als Schaltkanal-Reaktion konfiguriert und gilt unabh\u00e4ngig von der verwendeten Steuerungsmethode. <\/li>\n<li><strong>Futterpause und Wartung:<\/strong> Alle Steuerungsmethoden unterst\u00fctzen automatisches Pumpenverhalten w\u00e4hrend Futterpausen und Wartung. Siehe: <a href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/futterpause-wartung-stromausfall-konfigurationsanleitung\/\">Futterpause, Wartung &#038; Stromausfall \u2013 Konfigurationsanleitung<\/a> <\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Zusammenfassung Der ProfiLux unterst\u00fctzt mehrere Methoden zur Steuerung einer R\u00fcckf\u00f6rderpumpe, abh\u00e4ngig von Ihrem Pumpentyp und dem gew\u00fcnschten Grad der Kontrolle. Dieser Artikel erkl\u00e4rt die verf\u00fcgbaren Optionen und hilft Ihnen, den passenden Ansatz f\u00fcr Ihr Setup zu finden. Gilt f\u00fcr ProfiLux 4 Serie (inkl. Industrial Line \/ IL) ProfiLux 3 Serie Software: GHL Connect (App, Webinterface, myGHL) GHL Control Center Steuerungsmethoden GHL Versia Flow Die Versia Flow ist GHLs eigene drehzahlvariable R\u00fcckf\u00f6rderpumpe. Sie wird \u00fcber den Versia Controller und PAB an den ProfiLux angeschlossen und vollst\u00e4ndig \u00fcber Pumpengruppen verwaltet. Siehe: Versia \u2013 Einrichtungsanleitung Ein\/Aus-Steuerung \u00fcber Powerbar-Steckdose Die einfachste Option. Die R\u00fcckf\u00f6rderpumpe wird in eine Powerbar-Steckdose gesteckt und vom ProfiLux ein- oder ausgeschaltet. Nutzen Sie diese Option, wenn Ihre Pumpe keine Drehzahlregelung unterst\u00fctzt. Die Steckdose kann so konfiguriert werden, dass sie w\u00e4hrend Futterpausen oder Wartung automatisch abschaltet, und bei Bedarf mit einer Zeitschaltuhr geplant werden. Siehe: Schaltkan\u00e4le \u2013 Konfigurationsanleitung Durchfluss-Zeitpl\u00e4ne und -Programme&hellip;<\/p>\n","protected":false},"author":241,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"doc_category":[6214],"doc_tag":[],"class_list":["post-112789","docs","type-docs","status-publish","hentry","doc_category-durchfluss-stromungssteuerung","description-off"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>R\u00fcckf\u00f6rderpumpensteuerung \u2013 \u00dcberblick &amp; Anwendungsf\u00e4lle - GHL Advanced Technology<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"R\u00fcckf\u00f6rderpumpensteuerung \u2013 \u00dcberblick &amp; Anwendungsf\u00e4lle - GHL Advanced Technology\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle\/\" \/>\n<meta property=\"og:site_name\" content=\"GHL Advanced Technology\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/GHLGermany\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-14T12:08:47+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"2\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle\\\/\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle\\\/\",\"name\":\"R\u00fcckf\u00f6rderpumpensteuerung \u2013 \u00dcberblick & Anwendungsf\u00e4lle - GHL Advanced Technology\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#website\"},\"datePublished\":\"2026-09-14T12:08:47+00:00\",\"dateModified\":\"2026-09-14T12:08:47+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle\\\/#breadcrumb\"},\"inLanguage\":\"de-DE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Docs\",\"item\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/support\\\/knowledge-base\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"R\u00fcckf\u00f6rderpumpensteuerung \u2013 \u00dcberblick &#038; Anwendungsf\u00e4lle\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\",\"name\":\"GHL Advanced Technology\",\"description\":\"High-Tech for Aquariums, Aquaculture and Science, Made in Germany since 1998\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de-DE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#organization\",\"name\":\"GHL Advanced Technology\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de-DE\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2023\\\/11\\\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2023\\\/11\\\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp\",\"width\":512,\"height\":252,\"caption\":\"GHL Advanced Technology\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/GHLGermany\",\"https:\\\/\\\/www.instagram.com\\\/ghl_aquariumproducts\\\/\",\"https:\\\/\\\/www.tiktok.com\\\/@ghl_aquariumproducts\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"R\u00fcckf\u00f6rderpumpensteuerung \u2013 \u00dcberblick & Anwendungsf\u00e4lle - GHL Advanced Technology","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle\/","og_locale":"de_DE","og_type":"article","og_title":"R\u00fcckf\u00f6rderpumpensteuerung \u2013 \u00dcberblick & Anwendungsf\u00e4lle - GHL Advanced Technology","og_url":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle\/","og_site_name":"GHL Advanced Technology","article_publisher":"https:\/\/www.facebook.com\/GHLGermany","article_modified_time":"2026-09-14T12:08:47+00:00","twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"2\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle\/","url":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle\/","name":"R\u00fcckf\u00f6rderpumpensteuerung \u2013 \u00dcberblick & Anwendungsf\u00e4lle - GHL Advanced Technology","isPartOf":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#website"},"datePublished":"2026-09-14T12:08:47+00:00","dateModified":"2026-09-14T12:08:47+00:00","breadcrumb":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle\/#breadcrumb"},"inLanguage":"de-DE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/rueckfoerderpumpensteuerung-ueberblick-anwendungsfaelle\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.aquariumcomputer.com\/de\/"},{"@type":"ListItem","position":2,"name":"Docs","item":"https:\/\/www.aquariumcomputer.com\/de\/support\/knowledge-base\/"},{"@type":"ListItem","position":3,"name":"R\u00fcckf\u00f6rderpumpensteuerung \u2013 \u00dcberblick &#038; Anwendungsf\u00e4lle"}]},{"@type":"WebSite","@id":"https:\/\/www.aquariumcomputer.com\/de\/#website","url":"https:\/\/www.aquariumcomputer.com\/de\/","name":"GHL Advanced Technology","description":"High-Tech for Aquariums, Aquaculture and Science, Made in Germany since 1998","publisher":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aquariumcomputer.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de-DE"},{"@type":"Organization","@id":"https:\/\/www.aquariumcomputer.com\/de\/#organization","name":"GHL Advanced Technology","url":"https:\/\/www.aquariumcomputer.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de-DE","@id":"https:\/\/www.aquariumcomputer.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2023\/11\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp","contentUrl":"https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2023\/11\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp","width":512,"height":252,"caption":"GHL Advanced Technology"},"image":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/GHLGermany","https:\/\/www.instagram.com\/ghl_aquariumproducts\/","https:\/\/www.tiktok.com\/@ghl_aquariumproducts"]}]}},"year_month":"2026-10","word_count":426,"total_views":"6","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"thilo","author_nicename":"thilo","author_url":"https:\/\/www.aquariumcomputer.com\/de\/author\/thilo\/"},"doc_category_info":[{"term_name":"Durchfluss- &amp; Str\u00f6mungssteuerung","term_url":"https:\/\/www.aquariumcomputer.com\/de\/kbtopic\/durchfluss-stromungssteuerung\/"}],"doc_tag_info":[],"_links":{"self":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/112789","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/users\/241"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/comments?post=112789"}],"version-history":[{"count":8,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/112789\/revisions"}],"predecessor-version":[{"id":113701,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/112789\/revisions\/113701"}],"wp:attachment":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/media?parent=112789"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/doc_category?post=112789"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/doc_tag?post=112789"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}