{"id":113136,"date":"2026-07-08T12:00:21","date_gmt":"2026-07-08T10:00:21","guid":{"rendered":"https:\/\/www.aquariumcomputer.com\/knowledge-base\/dynamischer-sollwert-konfigurationsanleitung\/"},"modified":"2026-10-01T15:11:32","modified_gmt":"2026-10-01T13:11:32","password":"","slug":"dynamischer-sollwert-konfigurationsanleitung","status":"publish","type":"docs","link":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/dynamischer-sollwert-konfigurationsanleitung\/","title":{"rendered":"Dynamischer Sollwert \u2013 Konfigurationsanleitung"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Zusammenfassung<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Der Dynamische Sollwert verschiebt den Sollwert eines Sensors automatisch anhand des Istwerts eines anderen Sensors oder anhand einer Wertereihe aus einer hochgeladenen Datei \u2013 n\u00fctzlich zum Beispiel, um einen Temperatur-Sollwert schrittweise zu ver\u00e4ndern oder einer externen Referenzkurve zu folgen. Dieser Artikel behandelt die Verkn\u00fcpfung eines Sensors mit einem Kanal sowie die Konfiguration des Kanals selbst.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Gilt f\u00fcr<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<ul>\n<li>ProfiLux 4 Serie (inkl. Industrial Line \/ IL)<\/li>\n<li>ProfiLux 3 Serie<\/li>\n<li><strong>Software:<\/strong>\n<ul>\n<li>GHL Connect (App, Webinterface)<\/li>\n<li>GHL Control Center<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Bevor Sie beginnen<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<ul>\n<li>Der Dynamische Sollwert ist nur in der Expertenansicht verf\u00fcgbar.<\/li>\n<li>F\u00fcr allgemeine Sensoreinstellungen wie Regelung und Alarme siehe <a href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/sensoren-konfigurationsanleitung\/\">Sensoren \u2013 Konfigurationsanleitung<\/a>.<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Konfiguration<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h3>Dynamischen Sollwert f\u00fcr einen Sensor aktivieren<\/h3>\n<p>In den eigenen Einstellungen des Sensors, unter Dynamischer Sollwert:<\/p>\n<ul>\n<li><strong>Aktiv:<\/strong> Aktiviert den Dynamischen Sollwert f\u00fcr die Regelung dieses Sensors.<\/li>\n<li><strong>Aktueller Wert:<\/strong> Zeigt den aktuell vom Dynamischen Sollwert berechneten Sollwert an (nur lesbar).<\/li>\n<li><strong>Kanal:<\/strong> W\u00e4hlt aus, welchen Dynamischen-Sollwert-Kanal dieser Sensor verwendet.<\/li>\n<li>Schaltfl\u00e4che <strong>DNV-Kanal-Seite \u00f6ffnen<\/strong> <em>(nur GHL Connect App oder Webinterface):<\/em> \u00d6ffnet die Einstellungen des ausgew\u00e4hlten Kanals direkt.<\/li>\n<\/ul>\n<h3>Auf einen Dynamischen-Sollwert-Kanal zugreifen<\/h3>\n<ul>\n<li><strong>GHL Control Center:<\/strong> Gehen Sie zu <strong>Regelung -&gt; Dynamischer Sollwert X<\/strong>, wobei jeder Kanal aufgelistet und direkt ausw\u00e4hlbar ist.<\/li>\n<li><strong>GHL Connect App:<\/strong> \u00d6ffnen Sie die Einstellungsseite des betreffenden Sensors und verwenden Sie die oben beschriebene Schaltfl\u00e4che <strong>DNV-Kanal-Seite \u00f6ffnen<\/strong>.<\/li>\n<\/ul>\n<h3>Allgemeine Einstellungen<\/h3>\n<ul>\n<li><strong>Quelle des Dynamischen Sollwerts:<\/strong>\n<ul>\n<li><strong>Keine:<\/strong> Deaktiviert den Kanal.<\/li>\n<li><strong>Istwert eines Sensors:<\/strong> Verwendet den Istwert eines anderen Sensors als Grundlage f\u00fcr den Sollwert.<\/li>\n<li><strong>Datei:<\/strong> Verwendet eine Wertereihe aus einer hochgeladenen oder manuell eingegebenen Datenreihe.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Sensortyp:<\/strong> Legt fest, f\u00fcr welchen Sensortyp dieser Kanal einen Wert liefert. Dies gilt unabh\u00e4ngig von der gew\u00e4hlten Quelle und bestimmt den erwarteten Typ eines Quellsensors bzw. die Einheit der Werte in einer hochgeladenen Datei. <\/li>\n<li><strong>Offset:<\/strong> Wird zum Wert der ausgew\u00e4hlten Quelle addiert \u2013 dem Istwert des Quellsensors oder dem Wert aus der Datei \u2013 bevor dieser als Sollwert \u00fcbernommen wird.<\/li>\n<\/ul>\n<h3>Quellsensor<\/h3>\n<p><em>(Wenn Quelle auf \u201eIstwert eines Sensors&#8221; gesetzt ist)<\/em><\/p>\n<ul>\n<li><strong>Ist aus der PAB-Gruppe:<\/strong> W\u00e4hlt die PAB-Gruppe aus, zu der der Quellsensor geh\u00f6rt (\u00fcblicherweise 1 \u2014 eine spezielle PAB-Einstellung, die selten ben\u00f6tigt wird).<\/li>\n<li><strong>Hat in dieser Gruppe den Sensorindex:<\/strong> Der Index des Quellsensors innerhalb dieser PAB-Gruppe. Das GHL Control Center zeigt diesen Index direkt am Sensor in der Baumansicht an; die App zeigt ihn noch nicht an, er l\u00e4sst sich aber anhand der Reihenfolge in der Sensorliste abz\u00e4hlen, beginnend bei 1. <\/li>\n<\/ul>\n<h3>Dateiquelle<\/h3>\n<p><em>(Wenn Quelle auf \u201eDatei&#8221; gesetzt ist)<\/em><\/p>\n<ul>\n<li>Importieren Sie eine CSV-Datei, um deren Eintr\u00e4ge in eine Tabelle auf der Seite zu laden, oder f\u00fcgen Sie Eintr\u00e4ge manuell zur Tabelle hinzu. Bearbeiten oder l\u00f6schen Sie einzelne Zeilen nach Bedarf und laden Sie anschlie\u00dfend die Eintr\u00e4ge der Tabelle auf das Ger\u00e4t hoch. Eine vorhandene Datei kann auch aus dem Dateisystem des Ger\u00e4ts gel\u00f6scht werden.  <\/li>\n<li>Der Datei-Upload ist beim ProfiLux 3 nur im GHL Control Center und beim ProfiLux 4 nur in der App verf\u00fcgbar.<\/li>\n<li>Die Datei ist eine mit Semikolon getrennte CSV-Datei mit <strong>Datum<\/strong>, <strong>Zeit<\/strong> und <strong>Sollwert<\/strong> pro Zeile, ohne Kopfzeile \u2014 zum Beispiel: <code>01.12.2000;00:01;10,0<\/code><\/li>\n<li>Datum, Zeit und das Dezimaltrennzeichen in der Datei m\u00fcssen dem Format entsprechen, das auf dem System verwendet wird, auf dem GHL Control Center oder die App l\u00e4uft, sonst kann die Datei nicht korrekt eingelesen werden.<\/li>\n<li><strong>Jahr im Datum ignorieren:<\/strong> Wenn aktiviert, wiederholt sich der Zeitplan jedes Jahr, unabh\u00e4ngig vom Jahreswert des Datums. Wenn deaktiviert, gilt er nur f\u00fcr das jeweils in den Eintr\u00e4gen angegebene Jahr. <\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Zusammenfassung Der Dynamische Sollwert verschiebt den Sollwert eines Sensors automatisch anhand des Istwerts eines anderen Sensors oder anhand einer Wertereihe aus einer hochgeladenen Datei \u2013 n\u00fctzlich zum Beispiel, um einen Temperatur-Sollwert schrittweise zu ver\u00e4ndern oder einer externen Referenzkurve zu folgen. Dieser Artikel behandelt die Verkn\u00fcpfung eines Sensors mit einem Kanal sowie die Konfiguration des Kanals selbst. Gilt f\u00fcr ProfiLux 4 Serie (inkl. Industrial Line \/ IL) ProfiLux 3 Serie Software: GHL Connect (App, Webinterface) GHL Control Center Bevor Sie beginnen Der Dynamische Sollwert ist nur in der Expertenansicht verf\u00fcgbar. F\u00fcr allgemeine Sensoreinstellungen wie Regelung und Alarme siehe Sensoren \u2013 Konfigurationsanleitung. Konfiguration Dynamischen Sollwert f\u00fcr einen Sensor aktivieren In den eigenen Einstellungen des Sensors, unter Dynamischer Sollwert: Aktiv: Aktiviert den Dynamischen Sollwert f\u00fcr die Regelung dieses Sensors. Aktueller Wert: Zeigt den aktuell vom Dynamischen Sollwert berechneten Sollwert an (nur lesbar). Kanal: W\u00e4hlt aus, welchen Dynamischen-Sollwert-Kanal dieser Sensor verwendet. Schaltfl\u00e4che DNV-Kanal-Seite \u00f6ffnen&hellip;<\/p>\n","protected":false},"author":241,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"doc_category":[6206],"doc_tag":[],"class_list":["post-113136","docs","type-docs","status-publish","hentry","doc_category-sensoren-messungen","description-off"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Dynamischer Sollwert \u2013 Konfigurationsanleitung - GHL Advanced Technology<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/dynamischer-sollwert-konfigurationsanleitung\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Dynamischer Sollwert \u2013 Konfigurationsanleitung - GHL Advanced Technology\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/dynamischer-sollwert-konfigurationsanleitung\/\" \/>\n<meta property=\"og:site_name\" content=\"GHL Advanced Technology\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/GHLGermany\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-01T13:11:32+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"3\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/dynamischer-sollwert-konfigurationsanleitung\\\/\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/dynamischer-sollwert-konfigurationsanleitung\\\/\",\"name\":\"Dynamischer Sollwert \u2013 Konfigurationsanleitung - GHL Advanced Technology\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#website\"},\"datePublished\":\"2026-10-01T13:11:32+00:00\",\"dateModified\":\"2026-10-01T13:11:32+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/dynamischer-sollwert-konfigurationsanleitung\\\/#breadcrumb\"},\"inLanguage\":\"de-DE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/dynamischer-sollwert-konfigurationsanleitung\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/dynamischer-sollwert-konfigurationsanleitung\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Docs\",\"item\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/support\\\/knowledge-base\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Dynamischer Sollwert \u2013 Konfigurationsanleitung\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\",\"name\":\"GHL Advanced Technology\",\"description\":\"High-Tech for Aquariums, Aquaculture and Science, Made in Germany since 1998\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de-DE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#organization\",\"name\":\"GHL Advanced Technology\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de-DE\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2023\\\/11\\\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2023\\\/11\\\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp\",\"width\":512,\"height\":252,\"caption\":\"GHL Advanced Technology\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/GHLGermany\",\"https:\\\/\\\/www.instagram.com\\\/ghl_aquariumproducts\\\/\",\"https:\\\/\\\/www.tiktok.com\\\/@ghl_aquariumproducts\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Dynamischer Sollwert \u2013 Konfigurationsanleitung - GHL Advanced Technology","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/dynamischer-sollwert-konfigurationsanleitung\/","og_locale":"de_DE","og_type":"article","og_title":"Dynamischer Sollwert \u2013 Konfigurationsanleitung - GHL Advanced Technology","og_url":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/dynamischer-sollwert-konfigurationsanleitung\/","og_site_name":"GHL Advanced Technology","article_publisher":"https:\/\/www.facebook.com\/GHLGermany","article_modified_time":"2026-10-01T13:11:32+00:00","twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"3\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/dynamischer-sollwert-konfigurationsanleitung\/","url":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/dynamischer-sollwert-konfigurationsanleitung\/","name":"Dynamischer Sollwert \u2013 Konfigurationsanleitung - GHL Advanced Technology","isPartOf":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#website"},"datePublished":"2026-10-01T13:11:32+00:00","dateModified":"2026-10-01T13:11:32+00:00","breadcrumb":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/dynamischer-sollwert-konfigurationsanleitung\/#breadcrumb"},"inLanguage":"de-DE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/dynamischer-sollwert-konfigurationsanleitung\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/dynamischer-sollwert-konfigurationsanleitung\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.aquariumcomputer.com\/de\/"},{"@type":"ListItem","position":2,"name":"Docs","item":"https:\/\/www.aquariumcomputer.com\/de\/support\/knowledge-base\/"},{"@type":"ListItem","position":3,"name":"Dynamischer Sollwert \u2013 Konfigurationsanleitung"}]},{"@type":"WebSite","@id":"https:\/\/www.aquariumcomputer.com\/de\/#website","url":"https:\/\/www.aquariumcomputer.com\/de\/","name":"GHL Advanced Technology","description":"High-Tech for Aquariums, Aquaculture and Science, Made in Germany since 1998","publisher":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aquariumcomputer.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de-DE"},{"@type":"Organization","@id":"https:\/\/www.aquariumcomputer.com\/de\/#organization","name":"GHL Advanced Technology","url":"https:\/\/www.aquariumcomputer.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de-DE","@id":"https:\/\/www.aquariumcomputer.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2023\/11\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp","contentUrl":"https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2023\/11\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp","width":512,"height":252,"caption":"GHL Advanced Technology"},"image":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/GHLGermany","https:\/\/www.instagram.com\/ghl_aquariumproducts\/","https:\/\/www.tiktok.com\/@ghl_aquariumproducts"]}]}},"year_month":"2026-10","word_count":661,"total_views":"15","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"thilo","author_nicename":"thilo","author_url":"https:\/\/www.aquariumcomputer.com\/de\/author\/thilo\/"},"doc_category_info":[{"term_name":"Sensoren &amp; Messungen","term_url":"https:\/\/www.aquariumcomputer.com\/de\/kbtopic\/sensoren-messungen\/"}],"doc_tag_info":[],"_links":{"self":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/113136","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/users\/241"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/comments?post=113136"}],"version-history":[{"count":3,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/113136\/revisions"}],"predecessor-version":[{"id":114054,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/113136\/revisions\/114054"}],"wp:attachment":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/media?parent=113136"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/doc_category?post=113136"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/doc_tag?post=113136"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}