{"id":113586,"date":"2026-07-08T12:00:28","date_gmt":"2026-07-08T10:00:28","guid":{"rendered":"https:\/\/www.aquariumcomputer.com\/knowledge-base\/kh-director-fehlerbehebungsanleitung\/"},"modified":"2026-09-08T12:49:03","modified_gmt":"2026-09-08T10:49:03","password":"","slug":"kh-director-fehlerbehebungsanleitung","status":"publish","type":"docs","link":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-fehlerbehebungsanleitung\/","title":{"rendered":"KH Director \u2013 Fehlerbehebungsanleitung"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Zusammenfassung<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Diese Anleitung bietet umfassende Schritte zur Fehlerbehebung bei Messungenauigkeiten, physischen Installationsfehlern, Durchflussalarmen und Sensorkalibrierungsproblemen beim KH Director.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Gilt f\u00fcr<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<ul>\n<li>KH Director<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_tta-container\" data-vc-action=\"collapse\"><h2>Fehlerbehebung &amp; L\u00f6sungen<\/h2><div class=\"vc_general vc_tta vc_tta-accordion vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-o-shape-group vc_tta-controls-align-default\"><div class=\"vc_tta-panels-container\"><div class=\"vc_tta-panels\"><div class=\"vc_tta-panel\" id=\"physical-installation-errors\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h3 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#physical-installation-errors\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Physische Installationsfehler (h\u00e4ufigste Grundursache)<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h3><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4>Ursache<\/h4>\n<p>Die meisten Messprobleme lassen sich auf einen von drei physischen Installationsfehlern zur\u00fcckf\u00fchren und nicht auf einen Software- oder Hardwarefehler:<\/p>\n<ul>\n<li><strong>Falsches Schlauchmaterial:<\/strong> F\u00fcr die Reagenz-Leitung wird Standard-Silikonschlauch statt des mitgelieferten Flex-PVC verwendet. Silikon l\u00e4sst Luft diffundieren, was die Titrationsergebnisse mit der Zeit verschiebt.<\/li>\n<li><strong>Entl\u00fcftungsschlauch geknickt oder untergetaucht:<\/strong> Ein blockierter Entl\u00fcftungsschlauch verhindert den korrekten Druckausgleich innerhalb der Messzelle. Ist das offene Ende im Abfallbeh\u00e4lter untergetaucht, kann w\u00e4hrend der Abpumpphase Abwasser zur\u00fcck in das Ger\u00e4t gesaugt werden, was eine Kontamination riskiert.<\/li>\n<li><strong>Reagenz- und Referenzl\u00f6sung vertauscht:<\/strong> Die KH Reagenz wird f\u00fcr jede Titration ben\u00f6tigt; die KH Referenz dient nur zur \u00dcberpr\u00fcfung der Genauigkeit (siehe \u00dcberpr\u00fcfung der Messgenauigkeit weiter unten) und f\u00fchrt bei versehentlicher Dosierung zum Fehlschlagen der Titration.<\/li>\n<\/ul>\n<h4>L\u00f6sung<\/h4>\n<ul>\n<li><strong>Schlauchmaterial pr\u00fcfen:<\/strong> Stellen Sie sicher, dass entlang des gesamten Reagenz-Pfads (Flasche \u2192 Pumpe \u2192 KH Director) Flex-PVC-Schlauch verwendet wird.<\/li>\n<li><strong>Entl\u00fcftungsschlauch pr\u00fcfen:<\/strong> Stellen Sie sicher, dass er nicht blockiert ist und sein offenes Ende oberhalb der Wasserlinie des Abfallbeh\u00e4lters bleibt. Bemerken Sie Wasser im Entl\u00fcftungsschlauch, f\u00fchren Sie die Funktion <strong>&#8220;Messzelle vollst\u00e4ndig leeren&#8221;<\/strong> aus und pr\u00fcfen Sie erneut die Kalibrierung Ihrer Probe- und Abwasser-Pumpe.<\/li>\n<li><strong>Flaschenetiketten pr\u00fcfen:<\/strong> Pr\u00fcfen Sie die Etiketten, bevor Sie die Reagenz-Pumpe anschlie\u00dfen oder bef\u00fcllen.<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"inaccurate-fluctuating-results\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h3 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#inaccurate-fluctuating-results\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Ungenaue, schwankende oder driftende Messergebnisse<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h3><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4>Ursache: Luftblasen in der Reagenzleitung<\/h4>\n<p>Mikroblasen, die sich in der Reagenzleitung festsetzen, sind die h\u00e4ufigste Ursache f\u00fcr springende oder uneinheitliche Werte. Dies wird oft durch ungeeignete Schl\u00e4uche oder lose Verbindungen verursacht.<\/p>\n<h4>L\u00f6sung<\/h4>\n<ul>\n<li><strong>Flex-PVC verwenden:<\/strong> Stellen Sie sicher, dass der gesamte Reagenzpfad den mitgelieferten Flex-PVC-Schlauch verwendet, um Luftdiffusion zu verhindern.<\/li>\n<li><strong>System entl\u00fcften:<\/strong> Nutzen Sie die Funktion <strong>Internen Reagenz-Schlauch entl\u00fcften<\/strong>, bis absolut keine Mikroblasen mehr in der Leitung sichtbar sind.<\/li>\n<li><strong>Luftdichte Verbindungen:<\/strong> Pr\u00fcfen Sie alle Schlauchverbindungen und stellen Sie sicher, dass der Deckel der Reagenzflasche korrekt sitzt.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4>Ursache: Falsches Probenschlauchvolumen<\/h4>\n<p>Wenn das Volumen des Probenschlauchs (von der Wasserquelle zur Pumpe) nicht korrekt definiert ist, enth\u00e4lt die Titrationszelle nicht die genaue Wassermenge, die f\u00fcr eine korrekte Analyse ben\u00f6tigt wird.<\/p>\n<h4>L\u00f6sung<\/h4>\n<ul>\n<li><strong>Genau messen:<\/strong> Ermitteln Sie die exakte L\u00e4nge Ihres Probenschlauchs in cm.<\/li>\n<li><strong>Software-Rechner verwenden:<\/strong> Geben Sie die L\u00e4nge in den <strong>Schlauchvolumen-Rechner<\/strong> in den KH-Director-Einstellungen ein. Sch\u00e4tzen Sie das Volumen nicht selbst; lassen Sie es die Software anhand des Innendurchmessers des Schlauchs berechnen.<\/li>\n<li><strong>Filtervolumen:<\/strong> Stellen Sie sicher, dass die Option Inline-Filter-Volumen hinzuaddieren aktiviert ist, wenn Sie den GHL-Partikelfilter verwenden.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4>Ursache: pH-Sensor-Alterung oder -Ausfall<\/h4>\n<p>Der KH Director ben\u00f6tigt einen pr\u00e4zisen pH-Messwert, um den Titrationsendpunkt zu bestimmen. F\u00e4llt der Sensor aus, driften die Ergebnisse oder werden unstetig.<\/p>\n<h4>L\u00f6sung<\/h4>\n<ul>\n<li><strong>Kalibrierung pr\u00fcfen:<\/strong> F\u00fchren Sie eine 2-Punkt-Kalibrierung mit pH-4- und pH-7-Pufferl\u00f6sungen durch.<\/li>\n<li><strong>Austausch:<\/strong> L\u00e4sst sich der Sensor nicht mehr kalibrieren oder liegen die ADC-Werte zu nah beieinander, muss der Sensor ersetzt werden.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4>Ursache: Elektromagnetische St\u00f6rungen (EMI)<\/h4>\n<p>Hochspannungskabel oder -ger\u00e4te in der N\u00e4he des KH Director oder seines Sensorkabels k\u00f6nnen das empfindliche pH-Signal st\u00f6ren und zu schwankenden Ergebnissen f\u00fchren.<\/p>\n<h4>L\u00f6sung<\/h4>\n<p>Verlegen Sie das pH-Sensorkabel abseits von Stromkabeln gro\u00dfer Pumpen, Heizer oder LED-Vorschaltger\u00e4te. Stellen Sie sicher, dass der Stecker vollst\u00e4ndig in die R\u00fcckseite des KH Director eingesteckt ist.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"titration-too-long\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h3 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#titration-too-long\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">\u201eTitration dauert zu lange&quot;-Fehler<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h3><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4>Ursache: Probleme bei der Reagenzzufuhr oder falsche Fl\u00fcssigkeit<\/h4>\n<p>Fehlerhafte Reagenzzufuhr durch Luftblasen oder falsche Pumpenkalibrierung, versehentliche Verwendung von GHL-KH-Referenz statt Reagenz, oder \u00fcberm\u00e4\u00dfige Verd\u00fcnnung durch Restwasser in der Messzelle.<\/p>\n<h4>L\u00f6sung<\/h4>\n<ul>\n<li><strong>Fl\u00fcssigkeitstyp pr\u00fcfen:<\/strong> Stellen Sie sicher, dass Sie <strong>KH-Reagenz<\/strong> verwenden und nicht <strong>GHL-KH-Referenzl\u00f6sung<\/strong>.<\/li>\n<li><strong>Bef\u00fcllung:<\/strong> Pr\u00fcfen Sie, dass die Reagenzleitung vollst\u00e4ndig bef\u00fcllt und frei von Lufteinschl\u00fcssen ist.<\/li>\n<li><strong>Pumpengeschwindigkeit:<\/strong> Die Reagenz-Dosierpumpe muss kalibriert sein und bei <strong>Geschwindigkeit 0<\/strong> betrieben werden.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4>Ursache: Kalibrierung der Proben-\/Abwasserpumpe oder Zellenentleerung<\/h4>\n<p>Wird die Messzelle nach dem vorherigen Test nicht vollst\u00e4ndig entleert, oder liefert die Probenpumpe ein falsches Volumen, schl\u00e4gt die Titration fehl.<\/p>\n<h4>L\u00f6sung<\/h4>\n<ul>\n<li><strong>Kalibrierung pr\u00fcfen:<\/strong> Pr\u00fcfen Sie, dass Proben- und Abwasserpumpe korrekt kalibriert und auf <strong>Geschwindigkeit 3<\/strong> eingestellt sind.<\/li>\n<li><strong>Zelle leeren:<\/strong> F\u00fchren Sie die Funktion <strong>Messzelle vollst\u00e4ndig leeren<\/strong> aus, um einen trockenen Start f\u00fcr die n\u00e4chste Messung sicherzustellen.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4>Ursache: pH-Sensor-Problem<\/h4>\n<p>Ein alternder oder fehlerhafter pH-Sensor reagiert m\u00f6glicherweise zu langsam auf die Reagenzzugabe, sodass das System den Endpunkt nicht innerhalb des Sicherheitszeitfensters erkennen kann.<\/p>\n<h4>L\u00f6sung<\/h4>\n<p>F\u00fchren Sie eine neue 2-Punkt-pH-Kalibrierung durch. Ist die Reaktionszeit w\u00e4hrend der Kalibrierung (Wechsel zwischen pH 4 und pH 7) auff\u00e4llig langsam, ist der Sensor wahrscheinlich defekt und sollte ersetzt werden.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"verification-measurement-accuracy\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h3 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#verification-measurement-accuracy\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">\u00dcberpr\u00fcfung der Messgenauigkeit<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h3><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4>Vergleich mit manuellen Testkits<\/h4>\n<p>Manuelle Tropf-Testkits haben deutlich h\u00f6here Toleranzen und sind anf\u00e4llig f\u00fcr subjektive Interpretation (Farbumschlag) und Anwenderfehler. Sie sind kein verl\u00e4sslicher Ma\u00dfstab f\u00fcr die Laborgenauigkeit des KH Director.<\/p>\n<p>Vertrauen Sie eher dem Trend des KH Director als einzelnen manuellen Messungen. Bei Verdacht auf Ungenauigkeit f\u00fchren Sie immer einen Referenztest mit der <strong>GHL-KH-Referenzl\u00f6sung<\/strong> durch.<\/p>\n<p>&nbsp;<\/p>\n<h4>Durchf\u00fchrung eines Referenztests<\/h4>\n<p>Die Verwendung der <strong>GHL-KH-Referenzl\u00f6sung (7,5 \u00b0dKH)<\/strong> ist die einzig g\u00fcltige Methode, um die absolute Genauigkeit des Ger\u00e4ts zu \u00fcberpr\u00fcfen.<\/p>\n<p><strong>Vorgehensweise:<\/strong><\/p>\n<ol>\n<li>Entnehmen Sie den Probenwasserschlauch aus dem Aquarium\/Technikbecken.<\/li>\n<li>Wischen Sie das Schlauchende trocken und stecken Sie es in die Flasche mit der Referenzl\u00f6sung.<\/li>\n<li>F\u00fchren Sie mindestens 3 KH-Messungen unmittelbar hintereinander durch.<\/li>\n<li>Bei der 3. Messung sollte das Ergebnis im akzeptablen Bereich von <strong>7,1 \u00b0dKH \u2013 7,9 \u00b0dKH<\/strong> liegen, unter Ber\u00fccksichtigung der kombinierten Toleranzen von KH Director, Referenzl\u00f6sung und Reagenz.<\/li>\n<\/ol>\n<p><strong>Nach dem Test:<\/strong><\/p>\n<ol>\n<li>Entnehmen Sie den Schlauch aus der Flasche, wischen Sie ihn trocken und stecken Sie ihn wieder in das Aquarium\/Technikbecken.<\/li>\n<li>F\u00fchren Sie die Funktion <strong>&#8220;Messzelle sp\u00fclen&#8221;<\/strong> 1\u20132 Mal aus, um restliche Referenzfl\u00fcssigkeit aus den Leitungen zu entfernen, bevor Sie zum normalen Messplan zur\u00fcckkehren.<\/li>\n<\/ol>\n<p><em>Hinweis: Nach der R\u00fcckkehr zu Aquarienwasser kann es bis zu 3 Messzyklen dauern, bis der angezeigte KH-Wert wieder genau die tats\u00e4chliche Karbonath\u00e4rte Ihres Beckens widerspiegelt.<\/em><\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"ph-calibration-fails\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h3 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#ph-calibration-fails\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">pH-Sensor-Kalibrierung schl\u00e4gt fehl<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h3><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4>Ursache: Umgang mit Pufferl\u00f6sung oder Kontamination<\/h4>\n<p>\u00c4ltere Pufferl\u00f6sungen k\u00f6nnen zwar verwendet werden, kontaminierte Puffer f\u00fchren jedoch zu einem Fehlschlagen der Kalibrierung.<\/p>\n<h4>L\u00f6sung<\/h4>\n<ul>\n<li><strong>Richtiger Umgang:<\/strong> Sie k\u00f6nnen den Sensor direkt in die Pufferflaschen tauchen, m\u00fcssen die Sensorspitze aber vor dem Wechsel zwischen den Fl\u00fcssigkeiten <strong>mit einem sauberen Tuch trocken wischen<\/strong>, um Kreuzkontamination zu vermeiden.<\/li>\n<li><strong>Frische Puffer:<\/strong> Verwenden Sie im Zweifel eine frische, unkontaminierte Pufferl\u00f6sung.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4>Ursache: Hardwarefehler (Anschluss vs. Sensor)<\/h4>\n<p>Das Problem kann entweder am pH-Sensor selbst oder am Anschluss des KH Director liegen.<\/p>\n<h4>L\u00f6sung<\/h4>\n<ul>\n<li><strong>Kreuztest (Anschluss):<\/strong> Um festzustellen, ob der Anschluss defekt ist, versuchen Sie, einen anderen GHL-pH-Sensor (z. B. von einem ProfiLux) am KH-Director-Anschluss zu kalibrieren.<\/li>\n<li><strong>Kreuztest (Sensor):<\/strong> Alternativ versuchen Sie, den KH-Director-Sensor an einem ProfiLux-pH-Anschluss anzuschlie\u00dfen und zu kalibrieren.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h4>Ursache: Elektromagnetische St\u00f6rungen (EMI)<\/h4>\n<p>Hochspannungskabel oder -ger\u00e4te in der N\u00e4he des KH Director oder seines Sensorkabels k\u00f6nnen das empfindliche pH-Signal w\u00e4hrend der Kalibrierung st\u00f6ren.<\/p>\n<h4>L\u00f6sung<\/h4>\n<p>Verlegen Sie das pH-Sensorkabel abseits von Stromkabeln gro\u00dfer Pumpen, Heizer oder LED-Vorschaltger\u00e4te. Stellen Sie sicher, dass der Stecker vollst\u00e4ndig in die R\u00fcckseite des KH Director eingesteckt ist.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"measurement-fails-to-start\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h3 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#measurement-fails-to-start\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Messung startet nicht<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h3><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4>Ursache: PAB-Kommunikations- oder Zuordnungsprobleme<\/h4>\n<p>Der KH Director kann seine Pumpen nicht ansteuern, wenn der Doser nicht korrekt zugeordnet ist oder das PAB-Kabel lose sitzt.<\/p>\n<h4>L\u00f6sung<\/h4>\n<p>Pr\u00fcfen Sie die PAB-Zuordnung in der GHL Connect App oder in GHL Control Center. Pr\u00fcfen Sie, dass die PAB-Kabel fest eingesteckt sind und die Status-LEDs des Dosers einen normalen Zustand anzeigen.<\/p>\n<p>&nbsp;<\/p>\n<h4>Ursache: Niedriger Reagenzf\u00fcllstand<\/h4>\n<p>Erkennt der Controller, dass der berechnete F\u00fcllstand f\u00fcr die Reagenz zu niedrig ist, verhindert er den Start einer Messung, um zu vermeiden, dass Luft in die Messzelle gelangt.<\/p>\n<h4>L\u00f6sung<\/h4>\n<p>Pr\u00fcfen Sie den F\u00fcllstand in der GHL Connect App oder in GHL Control Center. Nach dem Nachf\u00fcllen oder Austauschen der Reagenzflasche m\u00fcssen Sie in der Software manuell die Funktion <strong>F\u00fcllstand auff\u00fcllen<\/strong> ausf\u00fchren, um die Messfunktion wieder zu aktivieren.<\/p>\n<p>&nbsp;<\/p>\n<h4>Ursache: Kein Doser \u00fcber PAB zugeordnet (nur bei ProfiLux-Controllern)<\/h4>\n<p>Der KH Director verf\u00fcgt \u00fcber keine eigenen internen Pumpen und ist f\u00fcr die Fl\u00fcssigkeitszufuhr vollst\u00e4ndig auf einen GHL Doser angewiesen. Ist \u00fcber PAB kein Doser zugeordnet, kann das System keine Messung starten.<\/p>\n<h4>L\u00f6sung<\/h4>\n<p>Stellen Sie sicher, dass ein GHL Doser korrekt \u00fcber PAB verbunden und in der Systemkonfiguration zugeordnet ist. Ohne eine g\u00fcltige PAB-Zuordnung fehlt dem KH Director die Hardware (Pumpen), die f\u00fcr einen Messzyklus ben\u00f6tigt wird.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Wann Sie den Support kontaktieren sollten<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Wenn Sie alle oben genannten Schritte zur Fehlerbehebung durchgef\u00fchrt haben und das Problem weiterhin besteht, er\u00f6ffnen Sie bitte ein Support-Ticket. Damit unser Team das Problem schnell diagnostizieren kann, geben Sie bitte eine kurze Zusammenfassung der Symptome und der bereits unternommenen Schritte an.<br \/>Sie erreichen unser Support-Team, indem Sie ein Ticket er\u00f6ffnen unter: <a href=\"https:\/\/www.aquariumcomputer.com\/support\/tickets-enquiries\/\">GHL Support Ticket System<\/a><\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Zusammenfassung Diese Anleitung bietet umfassende Schritte zur Fehlerbehebung bei Messungenauigkeiten, physischen Installationsfehlern, Durchflussalarmen und Sensorkalibrierungsproblemen beim KH Director. Gilt f\u00fcr KH Director Fehlerbehebung &amp; L\u00f6sungenPhysische Installationsfehler (h\u00e4ufigste Grundursache) Ursache Die meisten Messprobleme lassen sich auf einen von drei physischen Installationsfehlern zur\u00fcckf\u00fchren und nicht auf einen Software- oder Hardwarefehler: Falsches Schlauchmaterial: F\u00fcr die Reagenz-Leitung wird Standard-Silikonschlauch statt des mitgelieferten Flex-PVC verwendet. Silikon l\u00e4sst Luft diffundieren, was die Titrationsergebnisse mit der Zeit verschiebt. Entl\u00fcftungsschlauch geknickt oder untergetaucht: Ein blockierter Entl\u00fcftungsschlauch verhindert den korrekten Druckausgleich innerhalb der Messzelle. Ist das offene Ende im Abfallbeh\u00e4lter untergetaucht, kann w\u00e4hrend der Abpumpphase Abwasser zur\u00fcck in das Ger\u00e4t gesaugt werden, was eine Kontamination riskiert. Reagenz- und Referenzl\u00f6sung vertauscht: Die KH Reagenz wird f\u00fcr jede Titration ben\u00f6tigt; die KH Referenz dient nur zur \u00dcberpr\u00fcfung der Genauigkeit (siehe \u00dcberpr\u00fcfung der Messgenauigkeit weiter unten) und f\u00fchrt bei versehentlicher Dosierung zum Fehlschlagen der Titration. L\u00f6sung Schlauchmaterial pr\u00fcfen: Stellen Sie sicher, dass&hellip;<\/p>\n","protected":false},"author":241,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"doc_category":[6208],"doc_tag":[],"class_list":["post-113586","docs","type-docs","status-publish","hentry","doc_category-fehlerbehebung","description-off"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>KH Director \u2013 Fehlerbehebungsanleitung - GHL Advanced Technology<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-fehlerbehebungsanleitung\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"KH Director \u2013 Fehlerbehebungsanleitung - GHL Advanced Technology\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-fehlerbehebungsanleitung\/\" \/>\n<meta property=\"og:site_name\" content=\"GHL Advanced Technology\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/GHLGermany\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-08T10:49:03+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"9\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/kh-director-fehlerbehebungsanleitung\\\/\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/kh-director-fehlerbehebungsanleitung\\\/\",\"name\":\"KH Director \u2013 Fehlerbehebungsanleitung - GHL Advanced Technology\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#website\"},\"datePublished\":\"2026-09-08T10:49:03+00:00\",\"dateModified\":\"2026-09-08T10:49:03+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/kh-director-fehlerbehebungsanleitung\\\/#breadcrumb\"},\"inLanguage\":\"de-DE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/kh-director-fehlerbehebungsanleitung\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/kh-director-fehlerbehebungsanleitung\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Docs\",\"item\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/support\\\/knowledge-base\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"KH Director \u2013 Fehlerbehebungsanleitung\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\",\"name\":\"GHL Advanced Technology\",\"description\":\"High-Tech for Aquariums, Aquaculture and Science, Made in Germany since 1998\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de-DE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#organization\",\"name\":\"GHL Advanced Technology\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de-DE\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2023\\\/11\\\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2023\\\/11\\\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp\",\"width\":512,\"height\":252,\"caption\":\"GHL Advanced Technology\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/GHLGermany\",\"https:\\\/\\\/www.instagram.com\\\/ghl_aquariumproducts\\\/\",\"https:\\\/\\\/www.tiktok.com\\\/@ghl_aquariumproducts\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"KH Director \u2013 Fehlerbehebungsanleitung - GHL Advanced Technology","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-fehlerbehebungsanleitung\/","og_locale":"de_DE","og_type":"article","og_title":"KH Director \u2013 Fehlerbehebungsanleitung - GHL Advanced Technology","og_url":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-fehlerbehebungsanleitung\/","og_site_name":"GHL Advanced Technology","article_publisher":"https:\/\/www.facebook.com\/GHLGermany","article_modified_time":"2026-09-08T10:49:03+00:00","twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"9\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-fehlerbehebungsanleitung\/","url":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-fehlerbehebungsanleitung\/","name":"KH Director \u2013 Fehlerbehebungsanleitung - GHL Advanced Technology","isPartOf":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#website"},"datePublished":"2026-09-08T10:49:03+00:00","dateModified":"2026-09-08T10:49:03+00:00","breadcrumb":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-fehlerbehebungsanleitung\/#breadcrumb"},"inLanguage":"de-DE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-fehlerbehebungsanleitung\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-fehlerbehebungsanleitung\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.aquariumcomputer.com\/de\/"},{"@type":"ListItem","position":2,"name":"Docs","item":"https:\/\/www.aquariumcomputer.com\/de\/support\/knowledge-base\/"},{"@type":"ListItem","position":3,"name":"KH Director \u2013 Fehlerbehebungsanleitung"}]},{"@type":"WebSite","@id":"https:\/\/www.aquariumcomputer.com\/de\/#website","url":"https:\/\/www.aquariumcomputer.com\/de\/","name":"GHL Advanced Technology","description":"High-Tech for Aquariums, Aquaculture and Science, Made in Germany since 1998","publisher":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aquariumcomputer.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de-DE"},{"@type":"Organization","@id":"https:\/\/www.aquariumcomputer.com\/de\/#organization","name":"GHL Advanced Technology","url":"https:\/\/www.aquariumcomputer.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de-DE","@id":"https:\/\/www.aquariumcomputer.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2023\/11\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp","contentUrl":"https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2023\/11\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp","width":512,"height":252,"caption":"GHL Advanced Technology"},"image":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/GHLGermany","https:\/\/www.instagram.com\/ghl_aquariumproducts\/","https:\/\/www.tiktok.com\/@ghl_aquariumproducts"]}]}},"year_month":"2026-10","word_count":1707,"total_views":"26","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"thilo","author_nicename":"thilo","author_url":"https:\/\/www.aquariumcomputer.com\/de\/author\/thilo\/"},"doc_category_info":[{"term_name":"Fehlerbehebung","term_url":"https:\/\/www.aquariumcomputer.com\/de\/kbtopic\/fehlerbehebung\/"}],"doc_tag_info":[],"_links":{"self":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/113586","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/users\/241"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/comments?post=113586"}],"version-history":[{"count":2,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/113586\/revisions"}],"predecessor-version":[{"id":113588,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/113586\/revisions\/113588"}],"wp:attachment":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/media?parent=113586"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/doc_category?post=113586"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/doc_tag?post=113586"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}