{"id":113592,"date":"2026-07-08T12:00:28","date_gmt":"2026-07-08T10:00:28","guid":{"rendered":"https:\/\/www.aquariumcomputer.com\/knowledge-base\/kh-director-uebersicht-anwendungsfaelle\/"},"modified":"2026-09-08T14:11:25","modified_gmt":"2026-09-08T12:11:25","password":"","slug":"kh-director-uebersicht-anwendungsfaelle","status":"publish","type":"docs","link":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-uebersicht-anwendungsfaelle\/","title":{"rendered":"KH Director \u2013 \u00dcbersicht &#038; Anwendungsf\u00e4lle"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Zusammenfassung<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Der KH Director ist ein automatisiertes Mess- und Regelsystem zur \u00dcberwachung und Stabilisierung der Karbonath\u00e4rte (KH) in Meerwasseraquarien. Durch den Einsatz eines Labor-pH-Sensors und eines pr\u00e4zisen Titrationsverfahrens liefert er hochgenaue Daten und erm\u00f6glicht die automatisierte Regelung der KH ohne manuelle Tests.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Gilt f\u00fcr<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<ul>\n<li>KH Director<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>\u00dcbersicht<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Der KH Director nutzt ein automatisiertes S\u00e4ure-Base-Titrationsverfahren zur Messung der Karbonath\u00e4rte. Dies erm\u00f6glicht die Echtzeit\u00fcberwachung und pr\u00e4zise Steuerung von KH-Dosierpl\u00e4nen oder Kalziumreaktoren und sorgt so f\u00fcr eine stabile Wasserchemie. Der KH Director liefert hochpr\u00e4zise Daten speziell f\u00fcr die <strong>Karbonath\u00e4rte (KH \/ dKH)<\/strong>.<\/p>\n<p><i>Hinweis: F\u00fcr eine umfassende \u00dcberwachung Ihrer Wasserwerte l\u00e4sst sich der KH Director ideal mit dem ION Director kombinieren, der Kalzium, Magnesium, Kalium, Natrium und Nitrat \u00fcberwacht.<\/i><\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Funktionsweise<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Der KH Director automatisiert den klassischen Titrationsprozess, um Anwenderfehler und subjektive Interpretationen zu eliminieren, wie sie beim Absch\u00e4tzen von Farbumschl\u00e4gen bei manuellen Tropf-Testkits auftreten. F\u00fcr laborgenaue Pr\u00e4zision steuert er den gesamten Testzyklus eigenst\u00e4ndig:<\/p>\n<ul>\n<li><strong>Objektive Messung:<\/strong> Statt sich auf visuelle Farbumschl\u00e4ge zu verlassen, nutzt der KH Director eine Labor-pH-Elektrode, um den exakten Endpunkt der S\u00e4ure-Base-Titration zu bestimmen.<\/li>\n<li><strong>Vollautomatisierter Test:<\/strong> Das System entnimmt automatisch die ben\u00f6tigte Wasserprobe, dosiert pr\u00e4zise die KH-Reagenz und berechnet den exakten KH-Wert anhand der verwendeten Reagenzmenge.<\/li>\n<li><strong>Sichere Entsorgung:<\/strong> Nach Abschluss des Tests werden alle Fl\u00fcssigkeiten in einen separaten Abfallbeh\u00e4lter gepumpt. Es gelangt niemals Reagenz oder Testwasser zur\u00fcck ins Aquarium.<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Systemanforderungen<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Der KH Director ist Teil des GHL-\u00d6kosystems und ben\u00f6tigt spezifische Hardware zur Steuerung der Messlogik und Fl\u00fcssigkeitsf\u00f6rderung.<\/p>\n<ul>\n<li><strong>Ben\u00f6tigter Controller:<\/strong> Sie ben\u00f6tigen ein GHL-Ger\u00e4t mit PAB-Master-F\u00e4higkeit, z. B. einen <strong>ProfiLux 3<\/strong>, <strong>ProfiLux 4<\/strong> oder einen <strong>GHL Doser Standalone<\/strong>.<br \/>\n<i>Hinweis: GHL bietet verschiedene <strong>Starter-Sets<\/strong> an, die bereits einen Doser und den KH Director enthalten.<\/i><\/li>\n<li><strong>Ben\u00f6tigte Dosierpumpen:<\/strong> Auf einem <strong>GHL Doser<\/strong> werden drei dedizierte Pumpenk\u00f6pfe ben\u00f6tigt (Probenwasser, KH-Reagenz und Abwasser).<br \/>\n<i><strong>Wichtig: <\/strong>Es k\u00f6nnen nur Standard-GHL-Doser verwendet werden. Der KH Director ist f\u00fcr den Titrationsprozess <strong>nicht mit GHL-Doser-Maxi-Pumpen kompatibel<\/strong>.<\/i><\/li>\n<li><strong>Enthaltene Komponenten:<\/strong> Der KH Director wird mit einem Labor-<strong>pH-Sensor<\/strong>, <strong>KH-Reagenz<\/strong>, Kalibrierfl\u00fcssigkeiten und den ben\u00f6tigten <strong>Schl\u00e4uchen <\/strong>geliefert.<\/li>\n<li><strong>Kommunikation:<\/strong> Alle Ger\u00e4te sind \u00fcber das <strong>ProfiLux Aquatic Bus (PAB)<\/strong>-System f\u00fcr eine sichere, st\u00f6rungsfreie Daten\u00fcbertragung verbunden.<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Kernanwendungsf\u00e4lle<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4>Automatisierte \u00dcberwachung &#038; Alarmierung<\/h4>\n<p>Der KH Director macht subjektives manuelles Testen \u00fcberfl\u00fcssig, indem er Messungen in benutzerdefinierten Intervallen durchf\u00fchrt (z. B. von einmal t\u00e4glich bis mehrmals t\u00e4glich). Weichen die Werte vom gew\u00fcnschten Sollwert ab, kann das System Alarme ausl\u00f6sen oder Push-Benachrichtigungen \u00fcber die GHL Connect App senden.<\/p>\n<h4>Dynamische Dosiersteuerung<\/h4>\n<p>Das System kann Ihre Wasserchemie aktiv stabilisieren, indem es Ihren fl\u00fcssigen KH-Puffer-Dosierplan in Echtzeit anpasst. Es bietet zwei prim\u00e4re Modi zur Steuerung angeschlossener Dosierpumpen:<\/p>\n<ul>\n<li><strong>Add-On-Regelung:<\/strong> Der KH Director berechnet die Unterschreitung und f\u00fcgt Ihrem bestehenden Dosierplan eine zus\u00e4tzliche Dosis hinzu, um den Wert wieder auf den Sollwert zu bringen.<\/li>\n<li><strong>Adaptive Regelung:<\/strong> Das System skaliert automatisch Ihren gesamten Dosierplan (z. B. Ihre Balling- oder Triton-Grunddosen) prozentual nach oben oder unten, um dem aktuellen Verbrauch Ihres Riffs zu entsprechen.<\/li>\n<\/ul>\n<h4>Calciumreaktor- oder Kalkwasser-Steuerung<\/h4>\n<p>Anstelle der Anpassung fl\u00fcssiger Dosierpumpen kann der KH Director einen Calciumreaktor oder Kalkwasserr\u00fchrer steuern. Er kann die Reaktorleistung automatisch anpassen, indem er das CO2-Magnetventil schaltet oder eine drehzahlgeregelte F\u00f6rderpumpe basierend auf dem aktuellen KH-Messwert regelt, um eine perfekt stabile Karbonath\u00e4rte sicherzustellen.<\/p>\n<h4>Datenprotokollierung &#038; Trendanalyse<\/h4>\n<p>Alle Messdaten werden protokolliert und k\u00f6nnen im <strong>GHL Control Center<\/strong> oder \u00fcber GHL Connect eingesehen werden. So l\u00e4sst sich \u00fcber lange Zeitr\u00e4ume nachvollziehen, wie Ihr Aquarium auf Ver\u00e4nderungen bei Besatz, Meersalz-Marken oder Beleuchtung reagiert.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Zusammenfassung Der KH Director ist ein automatisiertes Mess- und Regelsystem zur \u00dcberwachung und Stabilisierung der Karbonath\u00e4rte (KH) in Meerwasseraquarien. Durch den Einsatz eines Labor-pH-Sensors und eines pr\u00e4zisen Titrationsverfahrens liefert er hochgenaue Daten und erm\u00f6glicht die automatisierte Regelung der KH ohne manuelle Tests. Gilt f\u00fcr KH Director \u00dcbersicht Der KH Director nutzt ein automatisiertes S\u00e4ure-Base-Titrationsverfahren zur Messung der Karbonath\u00e4rte. Dies erm\u00f6glicht die Echtzeit\u00fcberwachung und pr\u00e4zise Steuerung von KH-Dosierpl\u00e4nen oder Kalziumreaktoren und sorgt so f\u00fcr eine stabile Wasserchemie. Der KH Director liefert hochpr\u00e4zise Daten speziell f\u00fcr die Karbonath\u00e4rte (KH \/ dKH). Hinweis: F\u00fcr eine umfassende \u00dcberwachung Ihrer Wasserwerte l\u00e4sst sich der KH Director ideal mit dem ION Director kombinieren, der Kalzium, Magnesium, Kalium, Natrium und Nitrat \u00fcberwacht. Funktionsweise Der KH Director automatisiert den klassischen Titrationsprozess, um Anwenderfehler und subjektive Interpretationen zu eliminieren, wie sie beim Absch\u00e4tzen von Farbumschl\u00e4gen bei manuellen Tropf-Testkits auftreten. F\u00fcr laborgenaue Pr\u00e4zision steuert er den gesamten Testzyklus eigenst\u00e4ndig: Objektive&hellip;<\/p>\n","protected":false},"author":241,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"doc_category":[6211],"doc_tag":[],"class_list":["post-113592","docs","type-docs","status-publish","hentry","doc_category-erste-schritte","description-off"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>KH Director \u2013 \u00dcbersicht &amp; Anwendungsf\u00e4lle - GHL Advanced Technology<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-uebersicht-anwendungsfaelle\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"KH Director \u2013 \u00dcbersicht &amp; Anwendungsf\u00e4lle - GHL Advanced Technology\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-uebersicht-anwendungsfaelle\/\" \/>\n<meta property=\"og:site_name\" content=\"GHL Advanced Technology\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/GHLGermany\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-08T12:11:25+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"4\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/kh-director-uebersicht-anwendungsfaelle\\\/\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/kh-director-uebersicht-anwendungsfaelle\\\/\",\"name\":\"KH Director \u2013 \u00dcbersicht & Anwendungsf\u00e4lle - GHL Advanced Technology\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#website\"},\"datePublished\":\"2026-09-08T12:11:25+00:00\",\"dateModified\":\"2026-09-08T12:11:25+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/kh-director-uebersicht-anwendungsfaelle\\\/#breadcrumb\"},\"inLanguage\":\"de-DE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/kh-director-uebersicht-anwendungsfaelle\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/kh-director-uebersicht-anwendungsfaelle\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Docs\",\"item\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/support\\\/knowledge-base\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"KH Director \u2013 \u00dcbersicht &#038; Anwendungsf\u00e4lle\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\",\"name\":\"GHL Advanced Technology\",\"description\":\"High-Tech for Aquariums, Aquaculture and Science, Made in Germany since 1998\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de-DE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#organization\",\"name\":\"GHL Advanced Technology\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de-DE\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2023\\\/11\\\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2023\\\/11\\\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp\",\"width\":512,\"height\":252,\"caption\":\"GHL Advanced Technology\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/GHLGermany\",\"https:\\\/\\\/www.instagram.com\\\/ghl_aquariumproducts\\\/\",\"https:\\\/\\\/www.tiktok.com\\\/@ghl_aquariumproducts\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"KH Director \u2013 \u00dcbersicht & Anwendungsf\u00e4lle - GHL Advanced Technology","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-uebersicht-anwendungsfaelle\/","og_locale":"de_DE","og_type":"article","og_title":"KH Director \u2013 \u00dcbersicht & Anwendungsf\u00e4lle - GHL Advanced Technology","og_url":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-uebersicht-anwendungsfaelle\/","og_site_name":"GHL Advanced Technology","article_publisher":"https:\/\/www.facebook.com\/GHLGermany","article_modified_time":"2026-09-08T12:11:25+00:00","twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"4\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-uebersicht-anwendungsfaelle\/","url":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-uebersicht-anwendungsfaelle\/","name":"KH Director \u2013 \u00dcbersicht & Anwendungsf\u00e4lle - GHL Advanced Technology","isPartOf":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#website"},"datePublished":"2026-09-08T12:11:25+00:00","dateModified":"2026-09-08T12:11:25+00:00","breadcrumb":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-uebersicht-anwendungsfaelle\/#breadcrumb"},"inLanguage":"de-DE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-uebersicht-anwendungsfaelle\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/kh-director-uebersicht-anwendungsfaelle\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.aquariumcomputer.com\/de\/"},{"@type":"ListItem","position":2,"name":"Docs","item":"https:\/\/www.aquariumcomputer.com\/de\/support\/knowledge-base\/"},{"@type":"ListItem","position":3,"name":"KH Director \u2013 \u00dcbersicht &#038; Anwendungsf\u00e4lle"}]},{"@type":"WebSite","@id":"https:\/\/www.aquariumcomputer.com\/de\/#website","url":"https:\/\/www.aquariumcomputer.com\/de\/","name":"GHL Advanced Technology","description":"High-Tech for Aquariums, Aquaculture and Science, Made in Germany since 1998","publisher":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aquariumcomputer.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de-DE"},{"@type":"Organization","@id":"https:\/\/www.aquariumcomputer.com\/de\/#organization","name":"GHL Advanced Technology","url":"https:\/\/www.aquariumcomputer.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de-DE","@id":"https:\/\/www.aquariumcomputer.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2023\/11\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp","contentUrl":"https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2023\/11\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp","width":512,"height":252,"caption":"GHL Advanced Technology"},"image":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/GHLGermany","https:\/\/www.instagram.com\/ghl_aquariumproducts\/","https:\/\/www.tiktok.com\/@ghl_aquariumproducts"]}]}},"year_month":"2026-10","word_count":739,"total_views":"61","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"thilo","author_nicename":"thilo","author_url":"https:\/\/www.aquariumcomputer.com\/de\/author\/thilo\/"},"doc_category_info":[{"term_name":"Erste Schritte","term_url":"https:\/\/www.aquariumcomputer.com\/de\/kbtopic\/erste-schritte\/"}],"doc_tag_info":[],"_links":{"self":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/113592","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/users\/241"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/comments?post=113592"}],"version-history":[{"count":2,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/113592\/revisions"}],"predecessor-version":[{"id":113594,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/113592\/revisions\/113594"}],"wp:attachment":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/media?parent=113592"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/doc_category?post=113592"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/doc_tag?post=113592"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}