{"id":113600,"date":"2026-07-08T12:00:27","date_gmt":"2026-07-08T10:00:27","guid":{"rendered":"https:\/\/www.aquariumcomputer.com\/knowledge-base\/ghl-doser-fehlerbehebungsanleitung\/"},"modified":"2026-10-06T15:01:13","modified_gmt":"2026-10-06T13:01:13","password":"","slug":"ghl-doser-fehlerbehebungsanleitung","status":"publish","type":"docs","link":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ghl-doser-fehlerbehebungsanleitung\/","title":{"rendered":"GHL Doser \u2013 Fehlerbehebungsanleitung"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Zusammenfassung<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Diese Anleitung bietet L\u00f6sungen f\u00fcr die h\u00e4ufigsten Probleme mit GHL Dosern, darunter mechanische Unregelm\u00e4\u00dfigkeiten, Konfigurationsfehler und Kommunikationsprobleme.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Gilt f\u00fcr<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li>GHL Doser 2 \/ Maxi \/ 2.2 Maxi Serie (inkl. Industrial Line \/ IL)<\/li>\n<li>GHL Doser 3 \/ 3 Maxi Serie (inkl. Industrial Line \/ IL)<\/li>\n<li><strong>Kompatibler Controller:<\/strong>\n<\/li>\n<li>ProfiLux 4 Serie (inkl. Industrial Line \/ IL)<\/li>\n<li>ProfiLux 3 Serie<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\"><div class=\"vc_tta-container\" data-vc-action=\"collapse\"><h2>Fehlerbehebung &amp; L\u00f6sungen<\/h2><div class=\"vc_general vc_tta vc_tta-accordion vc_tta-color-grey vc_tta-style-classic vc_tta-shape-rounded vc_tta-o-shape-group vc_tta-controls-align-default\"><div class=\"vc_tta-panels-container\"><div class=\"vc_tta-panels\"><div class=\"vc_tta-panel\" id=\"inaccurate-dosing-or-leaking\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h3 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#inaccurate-dosing-or-leaking\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Ungenaue Dosiermengen oder Undichtigkeit<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h3><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4>Ursache<\/h4>\n<p>Wenn Hardware ausgetauscht wurde oder verschlissen ist, stimmt die tats\u00e4chliche F\u00f6rderrate nicht mehr mit den gespeicherten Softwarewerten \u00fcberein. Undichtigkeiten k\u00f6nnen auftreten, wenn Anschl\u00fcsse lose sind oder der interne Schlauch besch\u00e4digt ist.<\/p>\n<h4>L\u00f6sung<\/h4>\n<p>\u00d6ffnen Sie den Pumpenkopf und pr\u00fcfen Sie, ob der Schlauch korrekt eingelegt, nicht eingeklemmt und frei von Rissen ist. Stellen Sie sicher, dass die externen Schlauchanschl\u00fcsse fest sitzen. Nachdem die Hardware korrekt eingesetzt wurde oder Verschlei\u00dfteile ersetzt wurden, m\u00fcssen Sie eine neue Kalibrierung durchf\u00fchren, damit die Software die genaue F\u00f6rderrate der Pumpe kennt.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"pump-head-stalls\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h3 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#pump-head-stalls\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Pumpenkopf stockt, klickt oder dreht unregelm\u00e4\u00dfig<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h3><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4>Ursache: Mechanische Reibung<\/h4>\n<p>Mit der Zeit k\u00f6nnen Salzkriechen, Staub oder eingetrocknetes Werksfett (bei Doser 3 und Maxi Modellen) Reibung verursachen, die den Motor am gleichm\u00e4\u00dfigen Laufen hindert. Alternativ sitzt der Pumpenkopf m\u00f6glicherweise nicht korrekt auf der Motorwelle.<\/p>\n<h4>L\u00f6sung<\/h4>\n<p>\u00d6ffnen Sie den Pumpenkopf. Reinigen Sie alle Innenteile (Rollen, Drehteller und Geh\u00e4use) mit einem fusselfreien Tuch. Pr\u00fcfen Sie, ob der Kopf vollst\u00e4ndig auf die Motorwelle aufgeschoben ist.<\/p>\n<ul>\n<li><strong>F\u00fcr Doser 3 und Maxi Modelle:<\/strong> Tragen Sie erneut original GHL-Schmiermittel auf die beweglichen Teile auf.<\/li>\n<li><strong>F\u00fcr Doser 2 Modelle:<\/strong> Stellen Sie sicher, dass der Kopf vollst\u00e4ndig sauber und trocken bleibt \u2014 verwenden Sie hier <strong>niemals <\/strong>Schmiermittel, da dies die Funktion beeintr\u00e4chtigt.<\/li>\n<\/ul>\n<h4><\/h4>\n<h4>Ursache: Unzureichende Stromversorgung<\/h4>\n<p>Der Doser ist m\u00f6glicherweise an ein 12-V-Netzteil (z. B. von einem ProfiLux) statt an das erforderliche 24-V-Netzteil angeschlossen. Die 12-V-Einheit passt physisch, liefert aber nicht genug Drehmoment, um die Pumpen anzutreiben.<\/p>\n<h4>L\u00f6sung<\/h4>\n<p>Pr\u00fcfen Sie das Etikett auf Ihrem Netzteil. Stellen Sie sicher, dass dort eindeutig <strong>Output: 24V<\/strong> steht. Steht dort 12V, tauschen Sie es gegen das korrekte 24-V-Doser-Netzteil aus, um das volle Motordrehmoment wiederherzustellen.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"pump-does-not-follow-schedule\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h3 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#pump-does-not-follow-schedule\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Pumpe folgt nicht dem Zeitplan<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h3><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4>Ursache<\/h4>\n<p>Die Pumpenkonfiguration reagiert m\u00f6glicherweise auf einen Schaltkanal oder Niveausensor anstelle ihres internen Zeitplans, oder die \u201eTagemodus&#8221;-Einstellungen verhindern den Betrieb am aktuellen Datum (z. B. auf bestimmte Wochentage oder ein Tage-Intervall eingestellt, das noch nicht begonnen hat).<\/p>\n<h4>L\u00f6sung<\/h4>\n<p>Pr\u00fcfen Sie in den Pumpeneinstellungen \u00fcber GHL Connect oder GHL Control Center, ob im Bereich \u201ePumpe reagiert auf&#8221; <strong>der untenstehende Dosierplan<\/strong> ausgew\u00e4hlt ist. Kontrollieren Sie zus\u00e4tzlich, ob der <strong>Tagemodus<\/strong> (Wochentage oder Intervalle) das aktuelle Datum tats\u00e4chlich einschlie\u00dft.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"doser-ignores-schedule\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h3 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#doser-ignores-schedule\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Doser ignoriert seinen eigenen internen Dosierplan (nach Moduswechsel)<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h3><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4>Ursache<\/h4>\n<p>Wenn ein Doser von Standalone (SA) in den Extension-Modus (EXT) umgeschaltet wird, folgt er nicht mehr seiner eigenen internen Logik und seinen Zeitpl\u00e4nen, da er nun auf direkte Befehle von einem Master-Controller wartet.<\/p>\n<h4>L\u00f6sung<\/h4>\n<p>Pr\u00fcfen Sie den \u201eBetriebsmodus&#8221; in den allgemeinen Einstellungen von GHL Control Center oder GHL Connect. Ist der Modus auf <strong>EXT<\/strong> eingestellt, m\u00fcssen Sie alle Dosierpl\u00e4ne auf dem Master-Ger\u00e4t (ProfiLux oder Master-Doser) programmieren. Die EXT-Einheit reagiert dann nicht mehr auf Zeitpl\u00e4ne, die direkt auf seiner eigenen Oberfl\u00e4che programmiert wurden.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"speed-flow-settings-grayed-out\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h3 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#speed-flow-settings-grayed-out\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Einstellungen f\u00fcr Geschwindigkeit oder Durchfluss sind ausgegraut<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h3><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4>Ursache<\/h4>\n<p>Die Pumpe l\u00e4uft aktuell im Dauerlauf-Modus. Um Konfigurationskonflikte zu vermeiden, w\u00e4hrend die Pumpe im gleichm\u00e4\u00dfigen Dauerstrom l\u00e4uft, sperrt die Software diese bestimmten Felder.<\/p>\n<h4>L\u00f6sung<\/h4>\n<p>Wechseln Sie den Pumpenmodus kurzzeitig zu <strong>Automatische Zeiten<\/strong> oder <strong>Individuelle Zeiten<\/strong>. Dadurch werden die Felder entsperrt, sodass Sie die Geschwindigkeits- oder Durchflusswerte bearbeiten k\u00f6nnen. Nach der Anpassung k\u00f6nnen Sie den Modus wieder auf Dauerlauf-Modus umstellen.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"container-alarm-not-triggering\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h3 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#container-alarm-not-triggering\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Beh\u00e4lteralarm l\u00f6st nicht aus<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h3><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4>Ursache<\/h4>\n<p>Die Software ignoriert die F\u00fcllstandsberechnung, weil die \u00dcberwachung deaktiviert ist oder die erforderlichen Alarmschwellen und Ausl\u00f6ser nicht korrekt konfiguriert wurden.<\/p>\n<h4>L\u00f6sung<\/h4>\n<p>Stellen Sie sicher, dass <strong>F\u00fcllstands\u00fcberwachung abschalten<\/strong> nicht aktiviert ist. Pr\u00fcfen Sie, ob ein g\u00fcltiger <strong>Minimum-\/Maximum<\/strong>-Schwellenwert eingestellt ist und ob die Option <strong>Alarm wenn unter Min. \/ Alarm wenn \u00fcber Max.<\/strong> in den Beh\u00e4ltereinstellungen aktiv angehakt ist.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"ext-doser-not-found\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h3 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#ext-doser-not-found\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Master-Controller findet den EXT-Doser nicht<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h3><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4>Ursache<\/h4>\n<p>Der Doser kommuniziert aufgrund eines Verkabelungsproblems nicht mit dem Master-Controller \u00fcber den PAB-Bus, oder das Ger\u00e4t wurde im System nicht korrekt zugeordnet.<\/p>\n<h4>L\u00f6sung<\/h4>\n<p>Stellen Sie sicher, dass das PAB-Kabel fest in die richtigen PAB-Anschl\u00fcsse an beiden Ger\u00e4ten eingesteckt ist (nicht in den LAN-Anschluss). Pr\u00fcfen Sie, ob der EXT-Doser mit Strom versorgt wird.<\/p>\n<ul>\n<li><strong>In GHL Control Center:<\/strong> Navigieren Sie zur Seite <strong>System<\/strong> und klicken Sie auf <strong>Ger\u00e4te zuordnen<\/strong>.<\/li>\n<li><strong>In GHL Connect:<\/strong> Navigieren Sie zur Seite <strong>System<\/strong>, w\u00e4hlen Sie <strong>Zuordnen und konfigurieren der angeschlossenen PAB-Ger\u00e4te<\/strong> und klicken Sie anschlie\u00dfend auf <strong>Ger\u00e4te zuordnen<\/strong>.<\/li>\n<\/ul>\n<p>Wiederholen Sie die Suche, um den neu verbundenen Doser zu identifizieren und Ihrem Master-Ger\u00e4t zuzuordnen.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"erratic-after-doser-3-upgrade\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h3 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#erratic-after-doser-3-upgrade\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Pumpenverhalten ist fehlerhaft oder unstet nach der Installation des Doser 3 Pumpen Upgrade Kit<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h3><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4>Ursache<\/h4>\n<p>Die Doser-2-Hardware muss mitgeteilt bekommen, dass sie nun Doser-3-Pumpenk\u00f6pfe antreibt, wozu eine bestimmte Firmware-Version und eine Software-Einstellung erforderlich sind.<\/p>\n<h4>L\u00f6sung<\/h4>\n<ol>\n<li>Stellen Sie sicher, dass Ihre Doser-2-Firmware mindestens <strong>Version 1.55<\/strong> ist. Falls nicht, f\u00fchren Sie ein Firmwareupdate durch.<\/li>\n<li>Navigieren Sie je nach Oberfl\u00e4che und Ger\u00e4tetyp zur Konfigurationseinstellung:\n<ul>\n<li><strong>In GHL Control Center:<\/strong> Gehen Sie zur Seite <strong>System<\/strong>, w\u00e4hlen\/markieren Sie den Doser (Standalone oder EXT) im Ger\u00e4tebaum und klicken Sie auf <strong>Konfiguration<\/strong>.<\/li>\n<li><strong>In GHL Connect (Standalone):<\/strong> Gehen Sie zur Seite <strong>System<\/strong> und klicken Sie direkt auf <strong>Konfiguration<\/strong>.<\/li>\n<li><strong>In GHL Connect (EXT):<\/strong> Gehen Sie zur Seite <strong>System<\/strong>, w\u00e4hlen Sie <strong>Zuordnen und konfigurieren der angeschlossenen PAB-Ger\u00e4te<\/strong> und klicken Sie auf das <strong>Zahnradsymbol <\/strong>neben dem jeweiligen PAB-Ger\u00e4t.<\/li>\n<\/ul>\n<\/li>\n<li>Aktivieren Sie das Kontrollk\u00e4stchen <strong>\u201eDoser 3 Pumpenk\u00f6pfe-Upgrade vorhanden&#8221;<\/strong> und speichern Sie die \u00c4nderung.<\/li>\n<\/ol>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><div class=\"vc_tta-panel\" id=\"pump-numbering-conflict\" data-vc-content=\".vc_tta-panel-body\"><div class=\"vc_tta-panel-heading\"><h3 class=\"vc_tta-panel-title vc_tta-controls-icon-position-left\"><a href=\"#pump-numbering-conflict\" data-vc-accordion data-vc-container=\".vc_tta-container\"><span class=\"vc_tta-title-text\">Mehrere Doser reagieren auf dieselbe Pumpe \/ Pumpennummer<\/span><i class=\"vc_tta-controls-icon vc_tta-controls-icon-plus\"><\/i><\/a><\/h3><\/div><div class=\"vc_tta-panel-body\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h4>Ursache<\/h4>\n<p>Dieses Problem wird durch einen <strong>Nummerierungskonflikt<\/strong> verursacht. Standardm\u00e4\u00dfig ist jeder GHL Doser so konfiguriert, dass seine \u201eStartnummerierung&#8221; bei Index 1 beginnt. Werden mehrere Einheiten \u00fcber PAB verbunden, nummeriert das System sie nicht automatisch neu. Dadurch k\u00f6nnen sowohl der bestehende als auch der neue Doser versuchen, auf Befehle f\u00fcr \u201ePumpe 1-4&#8243; zu reagieren.<\/p>\n<h4>L\u00f6sung<\/h4>\n<p>Sie m\u00fcssen jedem Doser in der PAB-Kette manuell einen eindeutigen Startindex zuweisen:<\/p>\n<ol>\n<li><strong>Konfiguration \u00f6ffnen:<\/strong>\n<ul>\n<li><strong>In GHL Control Center:<\/strong> Gehen Sie zur Seite <strong>System<\/strong>, markieren Sie den Extension-Doser im Ger\u00e4tebaum und klicken Sie auf <strong>Konfiguration<\/strong>.<\/li>\n<li><strong>In GHL Connect:<\/strong> Navigieren Sie zur Seite <strong>System<\/strong>, w\u00e4hlen Sie <strong>Zuordnen und konfigurieren der angeschlossenen PAB-Ger\u00e4te<\/strong> und klicken Sie auf das <strong>Zahnradsymbol<\/strong> neben dem Doser.<\/li>\n<\/ul>\n<\/li>\n<li><strong>Startnummerierung festlegen:<\/strong> \u00c4ndern Sie den Wert auf die n\u00e4chste verf\u00fcgbare Pumpennummer und speichern Sie die \u00c4nderung.<br \/>\n<em>Beispiel: Wenn Ihr Master-Doser 4 Pumpen (1\u20134) nutzt, stellen Sie den ersten Extension-Doser auf <strong>Startnummerierung: 5<\/strong>.<\/em><\/li>\n<\/ol>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Wann Sie den Support kontaktieren sollten<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Wenn Sie alle oben genannten Schritte zur Fehlerbehebung durchgef\u00fchrt haben und das Problem weiterhin besteht, er\u00f6ffnen Sie bitte ein Support-Ticket. Damit unser Team das Problem schnell diagnostizieren kann, geben Sie bitte eine kurze Zusammenfassung der Symptome und der bereits unternommenen Schritte an.<br \/>Sie erreichen unser Support-Team, indem Sie ein Ticket er\u00f6ffnen unter: <a href=\"https:\/\/www.aquariumcomputer.com\/support\/tickets-enquiries\/\">GHL Support Ticket System<\/a><\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Zusammenfassung Diese Anleitung bietet L\u00f6sungen f\u00fcr die h\u00e4ufigsten Probleme mit GHL Dosern, darunter mechanische Unregelm\u00e4\u00dfigkeiten, Konfigurationsfehler und Kommunikationsprobleme. Gilt f\u00fcr GHL Doser 2 \/ Maxi \/ 2.2 Maxi Serie (inkl. Industrial Line \/ IL) GHL Doser 3 \/ 3 Maxi Serie (inkl. Industrial Line \/ IL) Kompatibler Controller: ProfiLux 4 Serie (inkl. Industrial Line \/ IL) ProfiLux 3 Serie Fehlerbehebung &amp; L\u00f6sungenUngenaue Dosiermengen oder Undichtigkeit Ursache Wenn Hardware ausgetauscht wurde oder verschlissen ist, stimmt die tats\u00e4chliche F\u00f6rderrate nicht mehr mit den gespeicherten Softwarewerten \u00fcberein. Undichtigkeiten k\u00f6nnen auftreten, wenn Anschl\u00fcsse lose sind oder der interne Schlauch besch\u00e4digt ist. L\u00f6sung \u00d6ffnen Sie den Pumpenkopf und pr\u00fcfen Sie, ob der Schlauch korrekt eingelegt, nicht eingeklemmt und frei von Rissen ist. Stellen Sie sicher, dass die externen Schlauchanschl\u00fcsse fest sitzen. Nachdem die Hardware korrekt eingesetzt wurde oder Verschlei\u00dfteile ersetzt wurden, m\u00fcssen Sie eine neue Kalibrierung durchf\u00fchren, damit die Software die genaue F\u00f6rderrate der Pumpe&hellip;<\/p>\n","protected":false},"author":241,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"doc_category":[6208],"doc_tag":[],"class_list":["post-113600","docs","type-docs","status-publish","hentry","doc_category-fehlerbehebung","description-off"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>GHL Doser \u2013 Fehlerbehebungsanleitung - GHL Advanced Technology<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ghl-doser-fehlerbehebungsanleitung\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"GHL Doser \u2013 Fehlerbehebungsanleitung - GHL Advanced Technology\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ghl-doser-fehlerbehebungsanleitung\/\" \/>\n<meta property=\"og:site_name\" content=\"GHL Advanced Technology\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/GHLGermany\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-06T13:01:13+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"7\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/ghl-doser-fehlerbehebungsanleitung\\\/\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/ghl-doser-fehlerbehebungsanleitung\\\/\",\"name\":\"GHL Doser \u2013 Fehlerbehebungsanleitung - GHL Advanced Technology\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#website\"},\"datePublished\":\"2026-10-06T13:01:13+00:00\",\"dateModified\":\"2026-10-06T13:01:13+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/ghl-doser-fehlerbehebungsanleitung\\\/#breadcrumb\"},\"inLanguage\":\"de-DE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/ghl-doser-fehlerbehebungsanleitung\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/ghl-doser-fehlerbehebungsanleitung\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Docs\",\"item\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/support\\\/knowledge-base\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"GHL Doser \u2013 Fehlerbehebungsanleitung\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\",\"name\":\"GHL Advanced Technology\",\"description\":\"High-Tech for Aquariums, Aquaculture and Science, Made in Germany since 1998\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de-DE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#organization\",\"name\":\"GHL Advanced Technology\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de-DE\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2023\\\/11\\\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2023\\\/11\\\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp\",\"width\":512,\"height\":252,\"caption\":\"GHL Advanced Technology\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/GHLGermany\",\"https:\\\/\\\/www.instagram.com\\\/ghl_aquariumproducts\\\/\",\"https:\\\/\\\/www.tiktok.com\\\/@ghl_aquariumproducts\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"GHL Doser \u2013 Fehlerbehebungsanleitung - GHL Advanced Technology","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ghl-doser-fehlerbehebungsanleitung\/","og_locale":"de_DE","og_type":"article","og_title":"GHL Doser \u2013 Fehlerbehebungsanleitung - GHL Advanced Technology","og_url":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ghl-doser-fehlerbehebungsanleitung\/","og_site_name":"GHL Advanced Technology","article_publisher":"https:\/\/www.facebook.com\/GHLGermany","article_modified_time":"2026-10-06T13:01:13+00:00","twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"7\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ghl-doser-fehlerbehebungsanleitung\/","url":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ghl-doser-fehlerbehebungsanleitung\/","name":"GHL Doser \u2013 Fehlerbehebungsanleitung - GHL Advanced Technology","isPartOf":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#website"},"datePublished":"2026-10-06T13:01:13+00:00","dateModified":"2026-10-06T13:01:13+00:00","breadcrumb":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ghl-doser-fehlerbehebungsanleitung\/#breadcrumb"},"inLanguage":"de-DE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ghl-doser-fehlerbehebungsanleitung\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ghl-doser-fehlerbehebungsanleitung\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.aquariumcomputer.com\/de\/"},{"@type":"ListItem","position":2,"name":"Docs","item":"https:\/\/www.aquariumcomputer.com\/de\/support\/knowledge-base\/"},{"@type":"ListItem","position":3,"name":"GHL Doser \u2013 Fehlerbehebungsanleitung"}]},{"@type":"WebSite","@id":"https:\/\/www.aquariumcomputer.com\/de\/#website","url":"https:\/\/www.aquariumcomputer.com\/de\/","name":"GHL Advanced Technology","description":"High-Tech for Aquariums, Aquaculture and Science, Made in Germany since 1998","publisher":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aquariumcomputer.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de-DE"},{"@type":"Organization","@id":"https:\/\/www.aquariumcomputer.com\/de\/#organization","name":"GHL Advanced Technology","url":"https:\/\/www.aquariumcomputer.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de-DE","@id":"https:\/\/www.aquariumcomputer.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2023\/11\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp","contentUrl":"https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2023\/11\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp","width":512,"height":252,"caption":"GHL Advanced Technology"},"image":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/GHLGermany","https:\/\/www.instagram.com\/ghl_aquariumproducts\/","https:\/\/www.tiktok.com\/@ghl_aquariumproducts"]}]}},"year_month":"2026-10","word_count":1420,"total_views":"60","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"thilo","author_nicename":"thilo","author_url":"https:\/\/www.aquariumcomputer.com\/de\/author\/thilo\/"},"doc_category_info":[{"term_name":"Fehlerbehebung","term_url":"https:\/\/www.aquariumcomputer.com\/de\/kbtopic\/fehlerbehebung\/"}],"doc_tag_info":[],"_links":{"self":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/113600","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/users\/241"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/comments?post=113600"}],"version-history":[{"count":4,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/113600\/revisions"}],"predecessor-version":[{"id":114187,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/113600\/revisions\/114187"}],"wp:attachment":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/media?parent=113600"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/doc_category?post=113600"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/doc_tag?post=113600"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}