{"id":114046,"date":"2026-07-08T12:00:22","date_gmt":"2026-07-08T10:00:22","guid":{"rendered":"https:\/\/www.aquariumcomputer.com\/knowledge-base\/sensoren-konfigurationsanleitung\/"},"modified":"2026-10-02T10:59:00","modified_gmt":"2026-10-02T08:59:00","password":"","slug":"sensoren-konfigurationsanleitung","status":"publish","type":"docs","link":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/sensoren-konfigurationsanleitung\/","title":{"rendered":"Sensoren \u2013 Konfigurationsanleitung"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Zusammenfassung<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>GHL-Controller k\u00f6nnen eine Vielzahl von Sensortypen auslesen, sie zur automatischen Regelung nutzen, Alarme ausl\u00f6sen und ihren Verlauf aufzeichnen. Dieser Artikel behandelt alle sensorbezogenen Einstellungen \u2014 Regelung, Alarme, sensorspezifische Parameter, virtuelle Sensoren und Messdatenaufzeichnung.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p><i>Ausf\u00fchrlichere Erl\u00e4uterungen zu einzelnen Einstellungen finden Sie in den ger\u00e4te\u00adspezifischen Programmierhandb\u00fcchern im Downloads-Bereich unten.<\/i><\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Gilt f\u00fcr<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<ul>\n<li>ProfiLux 4 Serie (inkl. Industrial Line \/ IL)<\/li>\n<li>ProfiLux 3 Serie<\/li>\n<li>ProfiLux Mini Serie<\/li>\n<li><strong>Software:<\/strong>\n<ul>\n<li>GHL Connect (App, Webinterface, myGHL)<\/li>\n<li>GHL Control Center<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Bevor Sie beginnen<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<ul>\n<li><strong>Unterst\u00fctzte Sensortypen:<\/strong> Temperatur, pH, Redox, Leitf\u00e4higkeit (S\u00fc\u00dfwasser, Meerwasser, Brackwasser), Luftfeuchtigkeit, Lufttemperatur, Sauerstoff, Spannung. Niveau-Sensoren und Durchfluss-Sensoren werden separat konfiguriert \u2014 siehe <a href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/niveauregelung-leckage-erkennung-einrichtungsanleitung\/\">Niveauregelung &#038; Leckage-Erkennung \u2013 Einrichtungsanleitung<\/a> und <a href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/durchfluss-sensoren-einrichtungsanleitung\/\">Durchflusssensoren \u2013 Einrichtungsanleitung<\/a>.<\/li>\n<li><strong>Anschluss:<\/strong> BNC-Sensoren werden entweder an einen integrierten Anschluss am ProfiLux, an eine ProfiLux-Erweiterungskarte oder an eine Expansion Box angeschlossen. Der analoge Temperatursensor nutzt einen Steckverbinder im PS\/2-Stil (ProfiLux 3 oder Erweiterungskarte), der Spannungssensor ben\u00f6tigt eine PLM-ADIN-Erweiterungskarte, und der Sauerstoffsensor ben\u00f6tigt eine eigene Erweiterungskarte.<\/li>\n<li><strong>Kalibrierung:<\/strong> pH-, Redox-, Leitf\u00e4higkeits- und Sauerstoffsensoren m\u00fcssen vor dem ersten Gebrauch sowie danach regelm\u00e4\u00dfig kalibriert werden \u2014 siehe <a href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/sensoren-wartung-kalibrierung\/\">Sensoren \u2013 Wartung &#038; Kalibrierung<\/a>.<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Konfiguration<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>\u00d6ffnen Sie die Einstellungen eines Sensors \u00fcber <strong>Regelung <\/strong>(GHL Control Center) bzw. <strong>Regelung -&gt;> Sensoren<\/strong> (GHL-Connect-App) und w\u00e4hlen Sie ihn aus der Liste aus. Eine <strong>Sensor\u00fcbersicht<\/strong>-Seite (GHL Control Center) bzw. die Sensorliste selbst (App) zeigt alle aktuellen Werte auf einen Blick. Einige der folgenden Einstellungen sind nur in der Expertenansicht sichtbar.<\/p>\n<h3>Grundeinstellungen<\/h3>\n<ul>\n<li><strong>Sensor aktiv:<\/strong> Aktiviert \u00dcberwachung und Regelung f\u00fcr diesen Sensor. Deaktivieren Sie ungenutzte Eing\u00e4nge, um Fehlalarme zu vermeiden.<\/li>\n<li><strong>Signalfilter:<\/strong> Gl\u00e4ttet kurzfristige Schwankungen des Messwerts.<\/li>\n<li><strong>Anzeige:<\/strong> W\u00e4hlt die angezeigte Ma\u00dfeinheit, sofern der Sensor mehr als eine unterst\u00fctzt.<\/li>\n<li><strong>Betriebsstunden:<\/strong> Erfasst, wie lange der Sensor bereits aktiv ist; kann manuell zur\u00fcckgesetzt werden.<\/li>\n<li><strong>Messbereich \u00e4ndern<\/strong> <em>(pH-, Redox- oder Leitf\u00e4higkeits-F\/S-Sensor; nur interne Sensoren; nicht beim ProfiLux Mini)<\/em>: Schaltet den Anschluss zwischen Messbereichen um (z. B. pH \u2194 Redox). Bei Sensoren an einer Erweiterungskarte oder Expansion Box erfolgt die Umschaltung stattdessen \u00fcber die PAB- bzw. Erweiterungskarten-Konfiguration.<\/li>\n<\/ul>\n<h3>Regelung<\/h3>\n<ul>\n<li><strong>Sollwert:<\/strong> Der Zielwert, auf den der Regler hinregelt.<\/li>\n<li><strong>Hysterese:<\/strong> Legt die Schaltpunkte um den Sollwert herum fest, um schnelles Ein-\/Ausschalten zu verhindern.<\/li>\n<li><strong>K\u00fchldifferenz <\/strong><em>(nur Temperatursensor)<\/em>: Zus\u00e4tzlicher Offset f\u00fcr die k\u00fchlungsbezogene Schaltung.<\/li>\n<li><strong>1-10V max. bei Abweichung um<\/strong> <em>(nur Temperatur- und Lufttemperatursensor)<\/em>: Legt die Abweichung vom Punkt, an dem die K\u00fchlung einschaltet \u2014 nicht vom Sollwert selbst \u2014 fest, bei der eine zugeordnete 1-10V-Schnittstelle die maximale Ausgabe erreicht.<\/li>\n<li><strong>Betriebsmodus Regler:<\/strong> Zweipunktregler (Standard), Puls\/Pause fest, Puls variabel, Pause variabel oder Aus. Zweipunkt deckt die meisten F\u00e4lle ab; die pulsbasierten Modi feinjustieren das Schaltverhalten f\u00fcr spezielle Aufbauten und erfordern eine <strong>Puls<\/strong>&#8211; und <strong>Pause<\/strong>-Dauer.<\/li>\n<li><strong>Bei Futterpause aus:<\/strong> Bei Aktivierung verh\u00e4lt sich der Sensor w\u00e4hrend einer Futterpause so, als w\u00e4re er inaktiv \u2014 der aktuelle Wert wird weiterhin angezeigt, aber Regelung und Alarm\u00fcberwachung werden bis zum Ende der Futterpause ausgesetzt.<\/li>\n<li>Um die berechneten Schaltpunkte f\u00fcr diese Regelung anzuzeigen, nutzen Sie die entsprechende Schaltfl\u00e4che in der App, oder pr\u00fcfen Sie die Tabelle am unteren Ende der Sensorseite in GHL Control Center.<\/li>\n<\/ul>\n<h3>N\u00e4chtliche \u00c4nderung<\/h3>\n<p><em>(nur Temperatur-, Lufttemperatur-, pH-, Spannungs- und Luftfeuchtigkeitssensoren)<\/em><\/p>\n<ul>\n<li><strong>Aktiv:<\/strong> Aktiviert eine zeitgesteuerte Anpassung des Sollwerts zwischen einer Start- und Endzeit.<\/li>\n<li><strong>\u00c4nderung um:<\/strong> Der Betrag, um den sich der Sollwert w\u00e4hrend des geplanten Zeitfensters verschiebt.<\/li>\n<li><strong>Startzeit \/ Endzeit:<\/strong> Legt das Zeitfenster fest, in dem die \u00c4nderung gilt.<\/li>\n<\/ul>\n<h3>Sensorspezifische Extras<\/h3>\n<ul>\n<li><strong>Sommerschaltung<\/strong> <em>(nur Temperatursensor)<\/em>: Aktiv-Umschalter plus eine Intensit\u00e4t-Einstellung f\u00fcr saisonales Schaltverhalten.<\/li>\n<li><strong>Temperaturkompensation<\/strong> <em>(nur Leitf\u00e4higkeits- und Sauerstoffsensoren)<\/em>: W\u00e4hlen Sie einen Referenz-Temperatursensor, oder geben Sie eine Man. Temperatur manuell ein, falls kein Sensor ausgew\u00e4hlt ist.<\/li>\n<li><strong>Salinit\u00e4t<\/strong> <em>(nur Sauerstoffsensor)<\/em>: W\u00e4hlen Sie einen Referenz-Leitf\u00e4higkeitssensor, oder geben Sie die Man. Salinit\u00e4t manuell ein.<\/li>\n<li><strong>Dichte-Offset<\/strong> <em>(nur Leitf\u00e4higkeits-Meerwasser-Sensor)<\/em>: Korrigiert den angezeigten Dichtewert, falls dieser von einer unabh\u00e4ngigen Referenzmessung (z. B. einem Refraktometer) abweicht.<\/li>\n<\/ul>\n<h3>Alarmeinstellungen<\/h3>\n<ul>\n<li><strong>Alarm:<\/strong> Aktiviert die Alarm\u00fcberwachung f\u00fcr diesen Sensor. In der App ist dies ein <strong>Aktiv<\/strong>-Umschalter plus eine separate Option <strong>Kein Alarm beim Wasserwechsel<\/strong> (nicht verf\u00fcgbar beim ProfiLux Mini). GHL Control Center fasst beides in einem Dropdown zusammen: <strong>Nicht aktiv<\/strong>, <strong>Aktiv <\/strong>oder <strong>Aktiv, au\u00dfer bei Wasserwechsel<\/strong>.<\/li>\n<li><strong>Regler abschalten:<\/strong> Schaltet die Regelung f\u00fcr diesen Sensor ab, solange ein Alarm aktiv ist.<\/li>\n<li><strong>Max. Abweichung:<\/strong> Die Abweichung vom Sollwert, die den Alarm ausl\u00f6st.<\/li>\n<li>Um die berechneten Alarmschwellen anzuzeigen, nutzen Sie die entsprechende Schaltfl\u00e4che in der App, oder pr\u00fcfen Sie die Tabelle am unteren Ende der Sensorseite in GHL Control Center.<\/li>\n<\/ul>\n<h3>Messdatenaufzeichnung<\/h3>\n<ul>\n<li><strong>App:<\/strong> Aktivieren Sie <strong>Messwerte aufzeichnen<\/strong> auf der Sensorseite, um dessen Messwerte aufzuzeichnen, und stellen Sie das <strong>Aufzeichnungsintervall<\/strong> ein (gilt f\u00fcr alle Sensoren).<\/li>\n<li><strong>GHL Control Center:<\/strong> Legen Sie unter <strong>Regelung -&gt; Messdaten<\/strong> fest, welche Sensoren aufgezeichnet werden sollen, und stellen Sie die Messperiode ein. Diese Seite zeigt au\u00dferdem die lokale Speichernutzung und erm\u00f6glicht es, ein Diagramm anzuzeigen, aufgezeichnete Werte zu exportieren oder die gespeicherten Daten zu l\u00f6schen.<\/li>\n<\/ul>\n<h3>Virtuelle Sensoren<\/h3>\n<ul>\n<li>Ein virtueller Sensor ist entweder eine Kopie eines physischen Sensors oder ein Mittelwert aus zwei physischen Sensoren desselben Typs \u2014 n\u00fctzlich, um z. B. eine separate Regelung auf derselben Messung laufen zu lassen (etwa zwei Heizungen, die auf unterschiedliche Sollwerte derselben Temperatursonde reagieren).<\/li>\n<li>Virtuelle Sensoren werden derzeit ausschlie\u00dflich \u00fcber das ProfiLux-Display erstellt und entfernt: <strong>System -&gt;> Virtu. Sensoren -&gt;> Neu vir. Sensor<\/strong>, dann den Typ (Kopie oder Mittelwert) und den\/die Quellsensor(en) ausw\u00e4hlen und mit Ja best\u00e4tigen. Zum Entfernen wiederholen Sie die ersten beiden Schritte und w\u00e4hlen den zu l\u00f6schenden virtuellen Sensor aus.<\/li>\n<li>Einmal erstellt, wird ein virtueller Sensor auf seiner eigenen Sensor-Einstellungsseite genau wie ein physischer Sensor konfiguriert (Regelung, Alarm usw.), nur ohne den Abschnitt Kalibrierdaten.<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Hinweise<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<ul>\n<li>Zur Kalibrierung und routinem\u00e4\u00dfigen Sensorwartung siehe <a href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/sensoren-wartung-kalibrierung\/\">Sensoren \u2013 Wartung &#038; Kalibrierung<\/a>.<\/li>\n<li>Zum automatischen Verschieben des Sollwerts eines Sensors basierend auf einem anderen Sensor oder einer Datei siehe <a href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/dynamischer-sollwert-konfigurationsanleitung\/\">Dynamischer Sollwert \u2013 Konfigurationsanleitung<\/a>.<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Downloads<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<ul>\n<li><a href=\"https:\/\/www.aquariumcomputer.com\/de\/document\/profilux-4-programmierhandbuch-v7-02\/\">ProfiLux 4 Programmierhandbuch<\/a><\/li>\n<li><a href=\"https:\/\/www.aquariumcomputer.com\/de\/document\/profilux-3-3-1-programmierhandbuch-v6-15\/\">ProfiLux 3 \/ 3.1 Programmierhandbuch<\/a><\/li>\n<li><a href=\"https:\/\/www.aquariumcomputer.com\/de\/document\/profilux-mini-light-terra-programmierhandbuch-v1-02\/\">ProfiLux Mini \/ Light \/ Terra Programmierhandbuch<\/a><\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Zusammenfassung GHL-Controller k\u00f6nnen eine Vielzahl von Sensortypen auslesen, sie zur automatischen Regelung nutzen, Alarme ausl\u00f6sen und ihren Verlauf aufzeichnen. Dieser Artikel behandelt alle sensorbezogenen Einstellungen \u2014 Regelung, Alarme, sensorspezifische Parameter, virtuelle Sensoren und Messdatenaufzeichnung. Ausf\u00fchrlichere Erl\u00e4uterungen zu einzelnen Einstellungen finden Sie in den ger\u00e4te\u00adspezifischen Programmierhandb\u00fcchern im Downloads-Bereich unten. Gilt f\u00fcr ProfiLux 4 Serie (inkl. Industrial Line \/ IL) ProfiLux 3 Serie ProfiLux Mini Serie Software: GHL Connect (App, Webinterface, myGHL) GHL Control Center Bevor Sie beginnen Unterst\u00fctzte Sensortypen: Temperatur, pH, Redox, Leitf\u00e4higkeit (S\u00fc\u00dfwasser, Meerwasser, Brackwasser), Luftfeuchtigkeit, Lufttemperatur, Sauerstoff, Spannung. Niveau-Sensoren und Durchfluss-Sensoren werden separat konfiguriert \u2014 siehe Niveauregelung &#038; Leckage-Erkennung \u2013 Einrichtungsanleitung und Durchflusssensoren \u2013 Einrichtungsanleitung. Anschluss: BNC-Sensoren werden entweder an einen integrierten Anschluss am ProfiLux, an eine ProfiLux-Erweiterungskarte oder an eine Expansion Box angeschlossen. Der analoge Temperatursensor nutzt einen Steckverbinder im PS\/2-Stil (ProfiLux 3 oder Erweiterungskarte), der Spannungssensor ben\u00f6tigt eine PLM-ADIN-Erweiterungskarte, und der Sauerstoffsensor ben\u00f6tigt eine eigene Erweiterungskarte. Kalibrierung:&hellip;<\/p>\n","protected":false},"author":241,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"doc_category":[6206],"doc_tag":[],"class_list":["post-114046","docs","type-docs","status-publish","hentry","doc_category-sensoren-messungen","description-off"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Sensoren \u2013 Konfigurationsanleitung - GHL Advanced Technology<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/sensoren-konfigurationsanleitung\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Sensoren \u2013 Konfigurationsanleitung - GHL Advanced Technology\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/sensoren-konfigurationsanleitung\/\" \/>\n<meta property=\"og:site_name\" content=\"GHL Advanced Technology\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/GHLGermany\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-02T08:59:00+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"6\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/sensoren-konfigurationsanleitung\\\/\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/sensoren-konfigurationsanleitung\\\/\",\"name\":\"Sensoren \u2013 Konfigurationsanleitung - GHL Advanced Technology\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#website\"},\"datePublished\":\"2026-10-02T08:59:00+00:00\",\"dateModified\":\"2026-10-02T08:59:00+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/sensoren-konfigurationsanleitung\\\/#breadcrumb\"},\"inLanguage\":\"de-DE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/sensoren-konfigurationsanleitung\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/sensoren-konfigurationsanleitung\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Docs\",\"item\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/support\\\/knowledge-base\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Sensoren \u2013 Konfigurationsanleitung\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\",\"name\":\"GHL Advanced Technology\",\"description\":\"High-Tech for Aquariums, Aquaculture and Science, Made in Germany since 1998\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de-DE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#organization\",\"name\":\"GHL Advanced Technology\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de-DE\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2023\\\/11\\\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2023\\\/11\\\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp\",\"width\":512,\"height\":252,\"caption\":\"GHL Advanced Technology\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/GHLGermany\",\"https:\\\/\\\/www.instagram.com\\\/ghl_aquariumproducts\\\/\",\"https:\\\/\\\/www.tiktok.com\\\/@ghl_aquariumproducts\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Sensoren \u2013 Konfigurationsanleitung - GHL Advanced Technology","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/sensoren-konfigurationsanleitung\/","og_locale":"de_DE","og_type":"article","og_title":"Sensoren \u2013 Konfigurationsanleitung - GHL Advanced Technology","og_url":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/sensoren-konfigurationsanleitung\/","og_site_name":"GHL Advanced Technology","article_publisher":"https:\/\/www.facebook.com\/GHLGermany","article_modified_time":"2026-10-02T08:59:00+00:00","twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"6\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/sensoren-konfigurationsanleitung\/","url":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/sensoren-konfigurationsanleitung\/","name":"Sensoren \u2013 Konfigurationsanleitung - GHL Advanced Technology","isPartOf":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#website"},"datePublished":"2026-10-02T08:59:00+00:00","dateModified":"2026-10-02T08:59:00+00:00","breadcrumb":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/sensoren-konfigurationsanleitung\/#breadcrumb"},"inLanguage":"de-DE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/sensoren-konfigurationsanleitung\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/sensoren-konfigurationsanleitung\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.aquariumcomputer.com\/de\/"},{"@type":"ListItem","position":2,"name":"Docs","item":"https:\/\/www.aquariumcomputer.com\/de\/support\/knowledge-base\/"},{"@type":"ListItem","position":3,"name":"Sensoren \u2013 Konfigurationsanleitung"}]},{"@type":"WebSite","@id":"https:\/\/www.aquariumcomputer.com\/de\/#website","url":"https:\/\/www.aquariumcomputer.com\/de\/","name":"GHL Advanced Technology","description":"High-Tech for Aquariums, Aquaculture and Science, Made in Germany since 1998","publisher":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aquariumcomputer.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de-DE"},{"@type":"Organization","@id":"https:\/\/www.aquariumcomputer.com\/de\/#organization","name":"GHL Advanced Technology","url":"https:\/\/www.aquariumcomputer.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de-DE","@id":"https:\/\/www.aquariumcomputer.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2023\/11\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp","contentUrl":"https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2023\/11\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp","width":512,"height":252,"caption":"GHL Advanced Technology"},"image":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/GHLGermany","https:\/\/www.instagram.com\/ghl_aquariumproducts\/","https:\/\/www.tiktok.com\/@ghl_aquariumproducts"]}]}},"year_month":"2026-10","word_count":1118,"total_views":"29","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"thilo","author_nicename":"thilo","author_url":"https:\/\/www.aquariumcomputer.com\/de\/author\/thilo\/"},"doc_category_info":[{"term_name":"Sensoren &amp; Messungen","term_url":"https:\/\/www.aquariumcomputer.com\/de\/kbtopic\/sensoren-messungen\/"}],"doc_tag_info":[],"_links":{"self":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/114046","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/users\/241"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/comments?post=114046"}],"version-history":[{"count":5,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/114046\/revisions"}],"predecessor-version":[{"id":114081,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/114046\/revisions\/114081"}],"wp:attachment":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/media?parent=114046"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/doc_category?post=114046"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/doc_tag?post=114046"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}