{"id":114839,"date":"2026-10-29T08:52:12","date_gmt":"2026-10-29T07:52:12","guid":{"rendered":"https:\/\/www.aquariumcomputer.com\/knowledge-base\/ph-redox-sensoren-einfach-vs-doppeldiaphragma\/"},"modified":"2026-10-29T09:03:34","modified_gmt":"2026-10-29T08:03:34","password":"","slug":"ph-redox-sensoren-einfach-vs-doppeldiaphragma","status":"publish","type":"docs","link":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ph-redox-sensoren-einfach-vs-doppeldiaphragma\/","title":{"rendered":"pH- &#038; Redox-Sensoren \u2013 Einfach- vs. Doppeldiaphragma"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Zusammenfassung<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>pH- und Redox-Sensoren (ORP) gibt es mit zwei unterschiedlichen Bauformen der Referenzzelle: mit Einfachdiaphragma und mit Doppeldiaphragma. Dieser Artikel erkl\u00e4rt den Unterschied zwischen beiden Bauformen, wie er sich auf die Zuverl\u00e4ssigkeit der Messung und die Lebensdauer des Sensors auswirkt und welchen Typ GHL verwendet.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Gilt f\u00fcr<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<ul>\n<li>GHL pH-Sensoren<\/li>\n<li>GHL Redox-Sensoren<\/li>\n<li>KH Director (pH-Sensor)<\/li>\n<li><strong>Kompatibler Controller:<\/strong>\n<ul>\n<li>ProfiLux 4 Serie (inkl. Industrial Line \/ IL)<\/li>\n<li>ProfiLux 3 Serie<\/li>\n<li>ProfiLux Mini Serie<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Von GHL verwendeter Sensortyp<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Zuverl\u00e4ssige Messergebnisse sind die Grundlage jeder automatischen Regelung. Daher verwendet GHL ausschlie\u00dflich pH- und Redox-Sensoren mit <strong>Doppeldiaphragma <\/strong>in Laborqualit\u00e4t. Das gilt auch f\u00fcr den pH-Sensor des KH Director.<\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div><div class=\"vc_row wpb_row vc_row-fluid\"><div class=\"wpb_column vc_column_container vc_col-sm-12\"><div class=\"vc_column-inner\"><div class=\"wpb_wrapper\">\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h2>Einfach- vs. Doppeldiaphragma<\/h2>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<p>Jeder pH- und Redox-Sensor enth\u00e4lt eine Referenzzelle, die mit einem Referenzelektrolyt gef\u00fcllt ist. Damit der Sensor funktioniert, muss dieser Referenzelektrolyt \u00fcber ein durchl\u00e4ssiges Diaphragma mit der Messl\u00f6sung in Kontakt stehen. Das Diaphragma ist f\u00fcr die Messung unverzichtbar, gleichzeitig aber auch das st\u00f6ranf\u00e4lligste Bauteil.<\/p>\n<ul>\n<li><strong>Einfachdiaphragma (Single Junction):<\/strong> Die Referenzzelle besitzt ein einzelnes Diaphragma, das direkt mit der Messl\u00f6sung in Kontakt steht. Verunreinigungen aus dem Aquarienwasser k\u00f6nnen dadurch relativ schnell in den Referenzelektrolyt gelangen.<\/li>\n<li><strong>Doppeldiaphragma (Double Junction):<\/strong> Zwischen Referenzzelle und Messl\u00f6sung befindet sich eine zweite Kammer, die mit demselben Referenzelektrolyt gef\u00fcllt ist. Die Referenzzelle ist \u00fcber ein eigenes Diaphragma mit dieser zweiten Kammer verbunden, und die zweite Kammer wiederum \u00fcber ein zweites Diaphragma mit der Messl\u00f6sung.<\/li>\n<\/ul>\n\n\t\t<\/div>\n\t<\/div>\n\n\t<div  class=\"wpb_single_image wpb_content_element vc_align_left\">\n\t\t\n\t\t<figure class=\"wpb_wrapper vc_figure\">\n\t\t\t<div class=\"vc_single_image-wrapper   vc_box_border_grey\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"622\" src=\"https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2019\/01\/DifferenceSingleJunctionDoubleJunctionProbe-600x622.webp\" class=\"vc_single_image-img attachment-woocommerce_single\" alt=\"\" title=\"DifferenceSingleJunctionDoubleJunctionProbe\" srcset=\"https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2019\/01\/DifferenceSingleJunctionDoubleJunctionProbe-600x622.webp 600w, https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2019\/01\/DifferenceSingleJunctionDoubleJunctionProbe-289x300.webp 289w, https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2019\/01\/DifferenceSingleJunctionDoubleJunctionProbe-768x796.webp 768w, https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2019\/01\/DifferenceSingleJunctionDoubleJunctionProbe-300x311.webp 300w, https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2019\/01\/DifferenceSingleJunctionDoubleJunctionProbe.webp 820w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\"  data-dt-location=\"https:\/\/www.aquariumcomputer.com\/de\/?attachment_id=77056\" \/><\/div>\n\t\t<\/figure>\n\t<\/div>\n\n\t<div class=\"wpb_text_column wpb_content_element \" >\n\t\t<div class=\"wpb_wrapper\">\n\t\t\t<h3>Vorteile des Doppeldiaphragmas<\/h3>\n<ul>\n<li><strong>Langsamere Verunreinigung:<\/strong> Die zweite Kammer wirkt als Puffer und verlangsamt die Verunreinigung des Referenzelektrolyts deutlich. Bei richtiger Pflege k\u00f6nnen Sensoren mit Doppeldiaphragma 12 Monate oder l\u00e4nger zuverl\u00e4ssig arbeiten.<\/li>\n<li><strong>Schutz vor Verstopfung:<\/strong> Manche Stoffe in der Messl\u00f6sung k\u00f6nnen mit dem Referenzelektrolyt reagieren und feste Ablagerungen bilden, die das Diaphragma verstopfen. Die zweite Kammer sch\u00fctzt die Referenzzelle vor diesem Effekt.<\/li>\n<li><strong>L\u00e4ngere Lebensdauer:<\/strong> Da Sensoren mit Einfachdiaphragma schneller verunreinigen, haben sie in der Regel eine sp\u00fcrbar k\u00fcrzere Lebensdauer als Sensoren mit Doppeldiaphragma.<\/li>\n<\/ul>\n<p><em>Hinweis: Auch Sensoren mit Doppeldiaphragma altern mit der Zeit. F\u00fcr genaue Messwerte sind weiterhin eine regelm\u00e4\u00dfige Kalibrierung und richtige Pflege erforderlich, siehe <a href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/sensoren-wartung-kalibrierung\/\">Sensoren \u2013 Wartung &#038; Kalibrierung<\/a>.<\/em><\/p>\n\n\t\t<\/div>\n\t<\/div>\n<\/div><\/div><\/div><\/div>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Zusammenfassung pH- und Redox-Sensoren (ORP) gibt es mit zwei unterschiedlichen Bauformen der Referenzzelle: mit Einfachdiaphragma und mit Doppeldiaphragma. Dieser Artikel erkl\u00e4rt den Unterschied zwischen beiden Bauformen, wie er sich auf die Zuverl\u00e4ssigkeit der Messung und die Lebensdauer des Sensors auswirkt und welchen Typ GHL verwendet. Gilt f\u00fcr GHL pH-Sensoren GHL Redox-Sensoren KH Director (pH-Sensor) Kompatibler Controller: ProfiLux 4 Serie (inkl. Industrial Line \/ IL) ProfiLux 3 Serie ProfiLux Mini Serie Von GHL verwendeter Sensortyp Zuverl\u00e4ssige Messergebnisse sind die Grundlage jeder automatischen Regelung. Daher verwendet GHL ausschlie\u00dflich pH- und Redox-Sensoren mit Doppeldiaphragma in Laborqualit\u00e4t. Das gilt auch f\u00fcr den pH-Sensor des KH Director. Einfach- vs. Doppeldiaphragma Jeder pH- und Redox-Sensor enth\u00e4lt eine Referenzzelle, die mit einem Referenzelektrolyt gef\u00fcllt ist. Damit der Sensor funktioniert, muss dieser Referenzelektrolyt \u00fcber ein durchl\u00e4ssiges Diaphragma mit der Messl\u00f6sung in Kontakt stehen. Das Diaphragma ist f\u00fcr die Messung unverzichtbar, gleichzeitig aber auch das st\u00f6ranf\u00e4lligste Bauteil. Einfachdiaphragma (Single&hellip;<\/p>\n","protected":false},"author":241,"featured_media":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"doc_category":[6206],"doc_tag":[],"class_list":["post-114839","docs","type-docs","status-publish","hentry","doc_category-sensoren-messungen","description-off"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>pH- &amp; Redox-Sensoren \u2013 Einfach- vs. Doppeldiaphragma - GHL Advanced Technology<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ph-redox-sensoren-einfach-vs-doppeldiaphragma\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"pH- &amp; Redox-Sensoren \u2013 Einfach- vs. Doppeldiaphragma - GHL Advanced Technology\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ph-redox-sensoren-einfach-vs-doppeldiaphragma\/\" \/>\n<meta property=\"og:site_name\" content=\"GHL Advanced Technology\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/GHLGermany\" \/>\n<meta property=\"article:modified_time\" content=\"2026-10-29T08:03:34+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data1\" content=\"2\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/ph-redox-sensoren-einfach-vs-doppeldiaphragma\\\/\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/ph-redox-sensoren-einfach-vs-doppeldiaphragma\\\/\",\"name\":\"pH- & Redox-Sensoren \u2013 Einfach- vs. Doppeldiaphragma - GHL Advanced Technology\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#website\"},\"datePublished\":\"2026-10-29T08:03:34+00:00\",\"dateModified\":\"2026-10-29T08:03:34+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/ph-redox-sensoren-einfach-vs-doppeldiaphragma\\\/#breadcrumb\"},\"inLanguage\":\"de-DE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/ph-redox-sensoren-einfach-vs-doppeldiaphragma\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/knowledge-base\\\/ph-redox-sensoren-einfach-vs-doppeldiaphragma\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Docs\",\"item\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/support\\\/knowledge-base\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"pH- &#038; Redox-Sensoren \u2013 Einfach- vs. Doppeldiaphragma\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#website\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\",\"name\":\"GHL Advanced Technology\",\"description\":\"High-Tech for Aquariums, Aquaculture and Science, Made in Germany since 1998\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de-DE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#organization\",\"name\":\"GHL Advanced Technology\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de-DE\",\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2023\\\/11\\\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp\",\"contentUrl\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2023\\\/11\\\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp\",\"width\":512,\"height\":252,\"caption\":\"GHL Advanced Technology\"},\"image\":{\"@id\":\"https:\\\/\\\/www.aquariumcomputer.com\\\/de\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/GHLGermany\",\"https:\\\/\\\/www.instagram.com\\\/ghl_aquariumproducts\\\/\",\"https:\\\/\\\/www.tiktok.com\\\/@ghl_aquariumproducts\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"pH- & Redox-Sensoren \u2013 Einfach- vs. Doppeldiaphragma - GHL Advanced Technology","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ph-redox-sensoren-einfach-vs-doppeldiaphragma\/","og_locale":"de_DE","og_type":"article","og_title":"pH- & Redox-Sensoren \u2013 Einfach- vs. Doppeldiaphragma - GHL Advanced Technology","og_url":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ph-redox-sensoren-einfach-vs-doppeldiaphragma\/","og_site_name":"GHL Advanced Technology","article_publisher":"https:\/\/www.facebook.com\/GHLGermany","article_modified_time":"2026-10-29T08:03:34+00:00","twitter_card":"summary_large_image","twitter_misc":{"Gesch\u00e4tzte Lesezeit":"2\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ph-redox-sensoren-einfach-vs-doppeldiaphragma\/","url":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ph-redox-sensoren-einfach-vs-doppeldiaphragma\/","name":"pH- & Redox-Sensoren \u2013 Einfach- vs. Doppeldiaphragma - GHL Advanced Technology","isPartOf":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#website"},"datePublished":"2026-10-29T08:03:34+00:00","dateModified":"2026-10-29T08:03:34+00:00","breadcrumb":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ph-redox-sensoren-einfach-vs-doppeldiaphragma\/#breadcrumb"},"inLanguage":"de-DE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ph-redox-sensoren-einfach-vs-doppeldiaphragma\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.aquariumcomputer.com\/de\/knowledge-base\/ph-redox-sensoren-einfach-vs-doppeldiaphragma\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.aquariumcomputer.com\/de\/"},{"@type":"ListItem","position":2,"name":"Docs","item":"https:\/\/www.aquariumcomputer.com\/de\/support\/knowledge-base\/"},{"@type":"ListItem","position":3,"name":"pH- &#038; Redox-Sensoren \u2013 Einfach- vs. Doppeldiaphragma"}]},{"@type":"WebSite","@id":"https:\/\/www.aquariumcomputer.com\/de\/#website","url":"https:\/\/www.aquariumcomputer.com\/de\/","name":"GHL Advanced Technology","description":"High-Tech for Aquariums, Aquaculture and Science, Made in Germany since 1998","publisher":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.aquariumcomputer.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de-DE"},{"@type":"Organization","@id":"https:\/\/www.aquariumcomputer.com\/de\/#organization","name":"GHL Advanced Technology","url":"https:\/\/www.aquariumcomputer.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de-DE","@id":"https:\/\/www.aquariumcomputer.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2023\/11\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp","contentUrl":"https:\/\/www.aquariumcomputer.com\/wp-content\/uploads\/sites\/3\/2023\/11\/cropped-cropped-Logo-balken_RGB_GHLBlau_freigestellt_mit-Abstand_512x512-1.webp","width":512,"height":252,"caption":"GHL Advanced Technology"},"image":{"@id":"https:\/\/www.aquariumcomputer.com\/de\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/GHLGermany","https:\/\/www.instagram.com\/ghl_aquariumproducts\/","https:\/\/www.tiktok.com\/@ghl_aquariumproducts"]}]}},"year_month":"2026-10","word_count":456,"total_views":"2","reactions":{"happy":"0","normal":"0","sad":"0"},"author_info":{"name":"thilo","author_nicename":"thilo","author_url":"https:\/\/www.aquariumcomputer.com\/de\/author\/thilo\/"},"doc_category_info":[{"term_name":"Sensoren &amp; Messungen","term_url":"https:\/\/www.aquariumcomputer.com\/de\/kbtopic\/sensoren-messungen\/"}],"doc_tag_info":[],"_links":{"self":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/114839","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs"}],"about":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/types\/docs"}],"author":[{"embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/users\/241"}],"replies":[{"embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/comments?post=114839"}],"version-history":[{"count":3,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/114839\/revisions"}],"predecessor-version":[{"id":114842,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/docs\/114839\/revisions\/114842"}],"wp:attachment":[{"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/media?parent=114839"}],"wp:term":[{"taxonomy":"doc_category","embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/doc_category?post=114839"},{"taxonomy":"doc_tag","embeddable":true,"href":"https:\/\/www.aquariumcomputer.com\/de\/wp-json\/wp\/v2\/doc_tag?post=114839"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}