How to setup a SHORT Timer function (seconds)

GHL Connect Android and iOS App

About SHORT Timer function

The timer function within the ProfiLux is a very versatile feature which can be used for performing different types of timer tasks. In this article we will focus on the SHORT timer function.

The SHORT timer mode allows you to run an ON /OFF timer function on a set schedule for short switching periods between 1s – 300s. This mode is especially useful for running equipment (connected to powerbar socket) such as a feeder.

Before you begin

  1. If you are not familiar yet with the operating concept of the ProfiLux Controller, we highly recommend to first read the Knowledgebase Article “How the ProfiLux Controller works“. It gives you an understanding of the basics and the operational concept of the controller.

Create the Timer function

  1. Press the Menu icon, select Processes
  2. Select an unused Timer function

3. Press the Switch mode tab, select Short, then type-in a description

Press SAVE when done.

4. Press the Schedule tab, press ADD and specify the time for when the timer shall activate and the duration of that event.

NOTE: The timer can be set to any number within the 1s – 300s range.

If you would like to have multiple ON / OFF times, press ADD again and specify the time and duration of that event.

5. Select a Day mode and specify how often to run this timer
6. Press SAVE

About Day mode

The Day mode you select will depend on how you wish to run the timer schedule

Special weekdays: Allows you to choose the days of the week to run this timer
Day intervals: Allows you to choose how often to run this timer in intervals.

For example, Repeat every 3 days = Timer will run every 3 days
Starting in — is a delay. If you want to delay the timer, specify by how many days.

Assign the Timer function

  1. Press the back-arrow, press the Menu icon, select Switch channels
  2. Select the Powerbar outlet that you want reacting to the timer function
  3. Type-in a description
  4. Set the function to TIMER and select the TIMER number you used when you created the function, then press SAVE

For example, if you created the function on TIMER 1, set the function to TIMER 1. If TIMER 2 was used, set the function to TIMER 2.

Alternate method via ProfiLux touch keys

If you wish to bypass GHL Connect, you can also create a Timer schedule by following these steps:

Create the Timer function

  1. Press the up or down arrow key
  2. Select Clock
  3. Select Timer
  4. Select an unused timer to edit
  5. Select Short for short cycle (seconds) ON / OFF schedule
  6. Specify how many times per day this timer will activate
  7. Select if this timer will activate on certain Days of week or Interval o.days
    Days of week: Allows you to specify specific days of the week to activate
    Interval: Allows you to specify the day-intervals; 1 = Daily… 2 = Every 2 days
  8. Specify Switch ON time and Switch OFF time
  9. Select YES to save changes

Assign the timer function

  1. Press the up or down arrow key
  2. Select System
  3. Select Sock.outl.func.
  4. Select the outlet that you want reacting to the Timer function
  5. Select Timer and select the Timer number where you created your schedule
  6. Set a Blackout delay, if necessary
  7. Select NO for Inv.sw.behavior
  8. Select YES to save changes