The GHL Doser 2.2 Standalone has a flow rate of up to 45 ml/minute which make it ideal for standard dosing quantities and small volume ATO / AWC (less than 1.5 gallons daily recommended).
Due to the precise 24 V stepper motors, micro-doses of 0.1 mL are also possible.
Robust mechanics and highly efficient stepper motors even allow continuous operation at a constant speed, e.g., for operating reactors.
The Doser 2.2 SA provides the flexibility to daisy chain multiple GHL Dosing Units (EXT models: Doser 2.x / 2.x Maxi) to control up to 16 dosing pumps in total. The ProfiLux Aquatic Bus provides reliable and interference-free data transfer, even over long distances up to 100 m (300 ft.).
Technical specifications:
Color: Black or white Dimensions: 8.66″ x 5.91″ x 3″ (without pumps)
*** EASY TO SETUP *** Completing the initial setup of a GHL device takes no more than 5 minutes with our in-app wizard!
Additional information
Product color
Black, Patriotic, White
About GHL Doser 2.2
Thanks to the high-quality technology inside the compactandmodernGHLDoser2.2, itprovides precise and straightforward dosing and includes many more features.With the freeGHLConnect Apporthecloud servicemyGHL, you can accessyourDoser from anywhere in the world tostartdispensing programs orcheck the levels of your metering liquids.
Its 24V stepper motors allow precise dosing even at the smallest flow rates (0.1 mL). Operate the device comfortably from your smartphone oryour PC. The connectionis possible viaWi-Fi andUSB.
TheLED-illuminatedGHLLogoin the housingserves as astatus indicator. It displays the condition of your aquarium by displaying various colors and tells you when something requires your attention.
TheGHLDoser2.2isavailable as a Stand Alone Unit and an Extension Unit.
GHL Doser 2.2 Stand Alone:
The GHL Doser 2.2 Stand Alone has a controller and works independently.
It includes two PAB ports for connecting additional GHL Doser 2.2 EXT or other PAB devices via ProfiLux Aquatic Bus.
PAB is an interference-free CAN-Bus-System that allows for highly secure data transfer between all PAB devices. The range can be up to 100 m (300 FT).
PAB cables are not included and must be purchased.
OneGHLDoser2.2 SA can control additional GHL EXT Dosers (GHL Doser 2.2 EXT or GHL Doser 2.2 Maxi EXT) and can be extended to a dosing system with a total of 16 pumps.
With a ProfiLux as a controller, you can control up to 32 pumps.
GHL Doser 2.2 EXT:
The GHL Doser 2.2 EXT needs to be controlled via a ProfiLux Controller or a GHL Doser 2.2 Maxi Stand Alone.
Features
Milliliter precision and automated dispensing of liquids, such as
Fertilizers
Trace Elements
Balling Salts
Lime Water
Liquid Feed
Integrated evaporated water refill (Auto Top–Off)
Automatic Water Change
Expandable to 16 pumps respectively, metering channels
Precise pumps with heavy-duty stepper motors
The pumps are suited for continuous operation
Stainless steel motor shafts (also suitable for the dosage of Iodine)
Sturdy construction, housingis made of aluminumanddurable plastic
Chemical-resistant tubing
Manual operation of each pump is possible
Pumps can be retrofitted
Individual parts can be replaced (tubes, pump head, motor)
24V stepper motors allow micro doses of 0.1 mL
Up to 150 doses per day
Easily choose dosing times via GHL Connect App and software (GHL Control Center).
Automatically: Up to 150 individual doses per day are automatically distributed
Individually: Up to 8 doses per day, individually set
Each pump can be set separately
Wide-range dose control Continuous mode: Min. 0.1 ml / minute, Max. 20 ml / minute,
Standard mode: Min. 0.1ml / minute, Max. 45 ml / minute
Level indicator
Wi-Fi and USB
Alarm function
Large LED status indicator
Status LED for pumps
Convenient to program via APP, cloud, web server, and free PC software
The LED-backlit GHL Logo in the enclosure lid is a status indicator. Various colors show you, at a glance, the condition of your system.
Each pump can be operated manually via the push buttons on the front panel. This allows you to quickly post-dose, deflate the tube vent, or suction liquids.
Ample accessories are available.
Delivery includes
GHL Doser 2.2
Power supply
4x Tubing adapters
6ft USB cable
Maintenance & Wear parts
Doser 2.2 pumps are largely maintenance-free. For optimal performance, we recommend occasionally cleaning and removing dust and other impurities from the inside of the pumps. The pumps must never be lubricated in any way!
Tubes, pumps and motors are wear parts, the life time depends on the use frequency, flow quantity and environmental conditions. When malfunctions (e.g. insufficient flow, losing prime, leakage, increased operation noise) or mechanical damages occur the wear parts must be replaced. Due to the maintenance-friendly design all wear parts can be replaced easily, all wear parts are available as accessories.
Related Knowledge-Base-Articles
We recommend you to read these articles in our Knowledge Base to learn more about this product:
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional
Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes.The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.