Bypass GHL Initial Setup: Connect to Device

Hi, Since you can see the GHLDEV hotspot, you can bypass the initial setup wizard and do the following to connect to your device: 1. Use your phone to connect to the GHLDEV hotspot2. Open the GHL Connect App3. Press ADD DEVICE -> Choose your device -> Create new connection -> Connection via GHL device hotspot4. Leave HOST/IP as-is, press NEXT, then name this connection Hotspot and press DONE Choose that newly made connection and when you see the Dashboard, you are connected. You can then proceed to the SYSTEM page where you can enter your Wi-Fi network info in the CLIENT settings.

IOND Statement Dec2024

we sincerely apologize for the delay in delivering your ION Director Multi-Ion Sensor and for our lack of updates. Our raw material supplier had persistent quality issues and production delays, and unfortunately, they did not respond to our repeated inquiries. This lack of communication hindered our ability to provide timely updates, and we deeply regret any frustration caused. The vendor has now shipped the needed materials to continue production. Including quality check and production time, we aim to begin shipping by the beginning of January.  We hope for your understanding and thank you for your patience.

IOND FW Update

While waiting for the sensor to arrive, I suggest you update your controller (ProfiLux4 or Doser SA) to version 7.41 (ProfiLux4) or 1.53 (DoserSA). The latest version of GHL Control Center 1.1.5.1, which includes this new firmware, says: “improved ION Director measurement algorithms: stronger sensor signals even with older sensors, increased accuracy and repeatability”. https://www.aquariumcomputer.com/downloads/ghl-control-center-1-1-5-1a/#changelog https://www.aquariumcomputer.com/knowledge-base/how-to-update-profilux-4-firmware/ https://www.aquariumcomputer.com/knowledge-base/how-to-update-standalone-doser-firmware/

WiFi fw update

Hello, You need to update the WiFi module firmware.To do this, go to http://1.2.3.4/update/ (REPLACE 1.2.3.4 with the ProfiLux’s current local IP address).Log in with admin and Starfish password (if you haven’t changed it).Load the firmware.bin file you previously extracted from the https://www.aquariumcomputer.com/downloads/wifi-module-esp-update/ zip file.  

IOND new orders

thank you for your enquiry! We have still so many IOND pre-orders to fulfil.Unfortunately, we don’t think that we can accept new orders before mid of the year, maybe it will even take until Autumn.Please subscribe for our newsletter to stay updated about our new products and when the IOND will be available to order again.You can subscribe here: https://www.aquariumcomputer.com/ (please scroll to the bottom of the page).

Instruction de retour FR

Voici nos instructions de retour : Veuillez envoyer le produit suffisamment affranchi et correctement protégé pour résister au transport à l’adresse suivante : GHL Advanced Technology GmbH & Co. KGMarie-Curie-Str.2067661 KaiserslauternAllemagne Veuillez noter que les envois non affranchis ne pourront pas être acceptés. Veuillez joindre le formulaire de réclamation ci-joint entièrement rempli (le plus important est la description du problème).    

Verification KHD

Bonjour, Quelques points à vérifier :  -> L’étalonnage de la pompe est très important : Utilisez une balance de précision (2 décimales). Étalonner avec de l’eau douce (sauf la pompe à réactif, qui peut être étalonnée avec du réactif, car sa densité est proche de celle de l’eau douce). Faire vider la pompe dans un récipient posé sur la balance (1g = 1ml si vous utilisez de l’eau douce). Effectuer plusieurs étalonnages successivement et vérifier que la valeur est quasiment constante (choisir la valeur moyenne).  Si la valeur varie beaucoup, il est temps de remplacer la tête de pompe doseuse (c’est une pièce d’usure). Veuillez noter que la tête de pompe à réactif peut devoir être remplacée si elle est usée, malgré un débit stable, car elle peut ne plus fonctionner correctement à des vitesses très faibles comme c’est le cas pendant le titrage. -> Pour déterminer le volume du tube d’échantillon, remplissez tout le tube…